Disopyramide determination by gas chromatography, liquid chromatography, and gas chromatography--mass spectrometry.
نویسندگان
چکیده
Disopyramide is determined in serum by gas chromatography with a nitrogen-selective detector, by liquid chromatography, and by gas chromatography--mass spectrometry. Comparable results are obtained with the three techniques, with a within-run and between-run precision of 5 to 10% (coefficient of variation). Least-squares analysis of data on patients' sera, analyzed first by gas chromatography (y) and then liquid chromatography (x), gave a slope of 1.12; y-intercept, -0.31; standard error of estimate, 0.46; and correlation coefficient, 0.94. Comparison of patients' sera by gas chromatography (y) and then by gas chromatography--mass spectrometry (x) gave a slope of 0.94; y-intercept, 0.42; standard error of estimate, 0.38; and correlation coefficient, 0.97. Interferences observed when using one technique--for example, gas chromatography--can be eliminated by analyzing the sample extract with one of the other techniques.
منابع مشابه
Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملDetection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography
Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...
متن کاملPerchloroethylene Analysis by Chemical Oxidation and Determination of Intermediate Products by Gas Chromatography, Mass Spectrometry
Abstract Background and Objective: Perchloroethylene (PCE) is a chlorinated hydrocarbon used as a solvent in many industrial processes. In contaminated water and soil a great deal of PCE is found. This study aimed to determine the rate of decomposition of PCE occurred after advanced oxidation. Material and Methods: In this descriptive-analytic study conducted (2011) in public health faculty...
متن کاملImpact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 11 شماره
صفحات -
تاریخ انتشار 1979