Polyethylene contact stresses, articular congruity, and knee alignment.

نویسندگان

  • D D D'Lima
  • P C Chen
  • C W Colwell
چکیده

Increased conformity at the tibiofemoral articulation increases contact area and reduces contact stresses in total knee arthroplasty. Malalignment, however, can increase polyethylene contact stresses. The effect of knee alignment and articular conformity on contact stresses was evaluated in a finite element model. The polyethylene insert and femoral component were modeled in high- and low-conformity conditions. An axial tibial load of 3000 N was applied across the tibiofemoral articulation at different knee positions ranging from 0 degrees, to 90 degrees, flexion, 0 to 10 mm anteroposterior translation, 0 degrees to 10 degrees axial rotation, and coronal plane angulation (liftoff). Increased conformity significantly reduced contact stresses in neutral alignment (by 44% at 0 degrees flexion and 36% at 60 degrees and 90 degrees flexion). Liftoff significantly increased contact stresses in low- and high-conformity conditions, but to a lesser degree in the high-conformity condition. Malalignment in rotation was most detrimental especially with the high-conformity insert design. Overall, increasing articular conformity reduced stresses when the knee was well-aligned. However, malalignment in axial rotation was detrimental. Mobile-bearing knee designs with increased articular congruity may result in lower contact stresses, especially the rotating-bearing designs that theoretically minimize rotational malalignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patellar polyethylene spinout after low-contact stress, high-congruity, mobile-bearing patellofemoral arthroplasty.

A low-contact stress, high-congruity, mobile-bearing patellofemoral joint arthroplasty decreases the contact force in the patellofemoral joint, theoretically reducing patellar polyethylene wear and increasing implant longevity. This article describes the case of a 47-year-old obese woman who presented with pain and loss of extension after a low-contact stress, high-congruity, mobile-bearing pat...

متن کامل

Osteochondral Grafting: Effect of Graft Alignment, Material Properties, and Articular Geometry

Osteochondral grafting for cartilage lesions is an attractive surgical procedure; however, the clinical results have not always been successful. Surgical recommendations differ with respect to donor site and graft placement technique. No clear biomechanical analysis of these surgical options has been reported. We hypothesized that differences in graft placement, graft biomechanical properties, ...

متن کامل

Patient-specific medial unicompartmental knee arthroplasty has a greater protective effect on articular cartilage in the lateral compartment

OBJECTIVES Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient's own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplas...

متن کامل

Predictions in Total Knee Replacements

Damage patterns on the articular surface of the proximal tibia, including cartilage degen23 eration in osteoarthritic knees and damage of polyethylene knee prostheses after total knee replacement, provide information related to knee joint biomechanics and damage 25 mechanisms at the articular surface. This study reports articular damage patterns and knee kinematics assessed in the knees of olde...

متن کامل

In vivo contact stresses during activities of daily living after knee arthroplasty.

We implanted an electronic knee prosthesis to measure tibial forces in vivo during activities of daily living after total knee arthroplasty. We used tibial forces and knee kinematic data collected in vivo to calculate contact stresses using finite element analysis. The polyethylene insert was modeled as an elastoplastic material, and predicted contact stresses were validated using pressure sens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 392  شماره 

صفحات  -

تاریخ انتشار 2001