Reproducibility of pulmonary function tests under laboratory and field conditions.

نویسندگان

  • R G Love
  • M D Attfield
  • K D Isles
چکیده

The reproducibility of pulmonary function tests in the laboratory and in a mobile field survey vehicle has been studied. Groups of laboratory workers were studied at base and a random sample of 38 coalminers was examined in the mobile laboratory. The intra-subject variability of some newer tests of lung function, including closing volume and maximum flow at low lung volumes, has been compared with that of well-established tests, such as lung volumes and forced expiratory volume from two measurements made more than one day apart. Most measurements were slightly less reproducible in the study of coalminers than in the laboratory personnel. Conventional tests, such as forced expiratory volume in one second, lung volumes, single breath CO transfer factor, and exercise ventilation were very reproducible, the coefficients of variation (cov) being generally between 5% and 10%. The closing volume test, maximum expiratory flow at low lung volumes, and the single breath N2 index were less reproducible: cov between 15% and 39% in the miners. The forced expired time and volume of isoflow, measured only on laboratory workers, however, exhibited greater reproducibility than previously reported (cov = 10% and 15% respectively). It is suggested that, when assessing the repeatability of lung function tests, account should be taken of the circumstances in which the intra-subject variability was measured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of remote limb ischemic preconditioning on pulmonary function tests and maximal oxygen uptake

Introduction: Ischemic preconditioning (IPC) protects skeletal muscles from ischemia-reperfusion injury and improves physical exercise performance. The purpose of the present study was to determine whether application of remote ischemic preconditioning (RIPC) of upper limbs would affect the pulmonary function tests and the maximal oxygen consumption (VO2max). Methods: Twenty healthy trained...

متن کامل

Spirometric evaluation of pulmonary function in Yazd’s dental laboratory workers in 1398

​abstract Introduction: Spirometry is a common device screening in occupational pulmonary disease. Dental laboratory workers usually are exposed to vapor, toxic gases, dust, metallic alloys, acrylics, and stones. Aim of This study was a Spirometric evaluation of the pulmonary function of Yazd’s dental laboratory workers. Method and materials: in this cross-sectional study 37 Yazd’dental tech...

متن کامل

CHRONIC OBSTRUCTIVE PULMONARY DISEASE Validity of spirometric testing in a general practice population of patients with chronic obstructive pulmonary disease (COPD)

Objective: To investigate the validity of spirometric tests performed in general practice. Method: A repeated within subject comparison of spirometric tests with a ‘‘gold standard’’ (spirometric tests performed in a pulmonary function laboratory) was performed in 388 subjects with chronic obstructive pulmonary disease (COPD) from 61 general practices and four laboratories. General practitioners...

متن کامل

Validity of spirometric testing in a general practice population of patients with chronic obstructive pulmonary disease (COPD).

OBJECTIVE To investigate the validity of spirometric tests performed in general practice. METHOD A repeated within subject comparison of spirometric tests with a "gold standard" (spirometric tests performed in a pulmonary function laboratory) was performed in 388 subjects with chronic obstructive pulmonary disease (COPD) from 61 general practices and four laboratories. General practitioners a...

متن کامل

Reproducibility of non-standardised autonomic function testing in the pre-operative assessment screening clinic*.

By convention, autonomic function tests are undertaken under standard test conditions that limit their implementation during routine pre-operative assessment. We therefore evaluated the comparability of autonomic function tests under both non-standardised and standardised test conditions in 20 healthy male subjects. Autonomic function was assessed using an ECG monitor and a continuous non-invas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 1980