Measurement comparison and Monte Carlo analysis for volumetric‐modulated arc therapy (VMAT) delivery verification using the ArcCHECK dosimetry system

نویسندگان

  • Mu‐Han Lin
  • Sion Koren
  • Iavor Veltchev
  • Jinsheng Li
  • Lu Wang
  • Robert A. Price
  • C.‐M. Ma
چکیده

The objective of this study is to validate the capabilities of a cylindrical diode array system for volumetric-modulated arc therapy (VMAT) treatment quality assurance (QA). The VMAT plans were generated by the Eclipse treatment planning system (TPS) with the analytical anisotropic algorithm (AAA) for dose calculation. An in-house Monte Carlo (MC) code was utilized as a validation tool for the TPS calculations and the ArcCHECK measurements. The megavoltage computed tomography (MVCT) of the ArcCHECK system was adopted for the geometry reconstruction in the TPS and for MC simulations. A 10 × 10 cm2 open field validation was performed for both the 6 and 10 MV photon beams to validate the absolute dose calibration of the ArcCHECK system and also the TPS dose calculations for this system. The impact of the angular dependency on noncoplanar deliveries was investigated with a series of 10 × 10 cm2 fields delivered with couch rotation 0° to 40°. The sensitivity of detecting the translational (1 to 10 mm) and the rotational (1° to 3°) misalignments was tested with a breast VMAT case. Ten VMAT plans (six prostate, H&N, pelvis, liver, and breast) were investigated to evaluate the agreement of the target dose and the peripheral dose among ArcCHECK measurements, and TPS and MC dose calculations. A customized acrylic plug holding an ion chamber was used to measure the dose at the center of the ArcCHECK phantom. Both the entrance and the exit doses measured by the ArcCHECK system with and without the plug agreed with the MC simulation to 1.0%. The TPS dose calculation with a 2.5 mm grid overestimated the exit dose by up to 7.2% when the plug was removed. The agreement between the MC and TPS calculations for the ArcCHECK without the plug improved significantly when a 1 mm dose calculation grid was used in the TPS. The noncoplanar delivery test demonstrated that the angular dependency has limited impact on the gamma passing rate (< 1.2% drop) for the 2%-3% dose and 2mm-3 mm DTA criteria. A 1° rotational misalignment introduces 11.3% (3%/3mm) to 21.3% (1%/1 mm) and 0.2% (3%/3 mm) to 0.8% (1%/1 mm) Gamma passing rate drop for ArcCHECK system and MatriXX system, respectively. Both systems have comparable sensitivity to the AP misalignments. However, a 2 mm RL misalignment introduces gamma passing rate drop ranging from 0.9% (3%/3 mm) to 4.0% (1%/1 mm) and 5.0% (3%/3 mm) to 12.0% (1%/1 mm) for ArcCHECK and MatriXX measurements, respectively. For VMAT plan QA, the gamma analysis passing rates ranged from 96.1% (H&N case) to 99.9% (prostate case), when using the 3%/3 mm DTA criteria for the peripheral dose validation between the TPS and ArcCHCEK measurements. The peripheral dose validation between the MC simulation and ArcCHECK measurements showed at least 97.9% gamma passing rates. The central dose validation also showed an agreement within 2.2% between TPS/MC calculations and ArcCHECK measurements. The worst discrepancy was found in the H&N case, which is the most complex VMAT case. The ArcCHECK system is suitable for VMAT QA evaluation based on the sensitivity to detecting misalignments, the clinical impact of the angular dependency, and the correlation between the dose agreements in the peripheral region and the central region. This work also demonstrated the importance of carrying out a thorough validation of both the TPS and the dosimetry system prior to utilizing it for QA, and the value of having an independent dose calculation tool, such as the MC method, in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA

We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric-modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response ...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy

Log file-based methods are attracting increasing interest owing to their ability to validate volumetric-modulated arc therapy outputs with high resolution in the leaf and gantry positions and in delivered dose. Cross-validation of these methods for comparison with measurement-based methods using the ionization chamber/ArcCHECK-3DVH software (version 3.2.0) under the same conditions of treatment...

متن کامل

Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013