Long-term results of catheter ablation of a posteroseptal accessory atrioventricular connection in 48 patients.
نویسندگان
چکیده
Forty-eight patients with a posteroseptal accessory atrioventricular (AV) connection underwent catheter ablation of the accessory AV connection with 200-400 J shocks delivered by a standard defibrillator. Cathodal shocks were delivered through the proximal pair of electrodes of a 6F quadripolar electrode catheter positioned in the coronary sinus such that the proximal electrodes straddled the ostium (12 patients) or the third electrode from the tip was at the ostium (36 patients). A 16-cm patch electrode positioned on the back or anterior chest served as the anode. Two to 4 shocks were delivered (total, 635 +/- 198 J, mean +/- SD). The cathether ablation procedure was clinically successful in eliminating symptomatic tachycardias in in 32 of 48 patients (67%) during a mean follow-up of 26 +/- 19 months. A long-term follow-up electrophysiology study was performed in 27 of the 32 patients who had a successful clinical outcome, and this showed that conduction through the accessory AV connection was completely absent in 25 patients and present but impaired in two patients. The success rate was significantly higher in patients with a concealed accessory AV connection (13 of 13, 100%) than in patients with manifest preexcitation (19 of 35, 54%; p less than 0.001). Among the 12 patients in whom the proximal electrodes of the ablation catheter straddled the ostium of the coronary sinus, one patient developed cardiac tamponade requiring needle pericardiocentesis; there were no instances of cardiac tamponade among the 36 patients in whom the third electrode from the tip was at the ostium of the coronary sinus. Other complications were AV block requiring a permanent pacemaker and transient atrial tachycardia in one patient each and an asymptomatic pericardial effusion in three patients. In conclusion, with the catheter ablation technique described in this study, a successful clinical outcome may be achieved in approximately two thirds of patients who have a posteroseptal accessory AV connection, and the risk of serious complications is low. This technique is particularly well suited to patients with a concealed posteroseptal accessory AV connection, in whom the success rate is higher than in patients with manifest preexcitation.
منابع مشابه
Efficacy and safety of transcatheter ablation of posteroseptal
Eight patients with a posteroseptal accessory pathway and symptomatic atrial fibrillation and/or orthodromic reciprocating tachycardia underwent attempted transcatheter ablation of the accessory pathway. A quadripolar electrode catheter was positioned within the coronary sinus such that the proximal pair of electrodes straddled the os. This proximal pair of electrodes was made electrically comm...
متن کاملRadiofrequency catheter ablation of accessory atrioventricular connections in 250 patients. Abbreviated therapeutic approach to Wolff-Parkinson-White syndrome.
BACKGROUND The purpose of this study was to report the results and complications of radiofrequency catheter ablation of accessory atrioventricular (AV) connections by using an abbreviated approach aimed at minimizing the duration of the procedure. METHODS AND RESULTS Two hundred fifty consecutive patients with the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardia invol...
متن کاملRadiofrequency Catheter Ablation of Accessory Atrioventricular Connections
or paroxysmal supraventricular tachycardia involving a concealed accessory AV connection underwent catheter ablation with the use of radiofrequency current. In 179 of the 250 patients, catheter ablation was performed at the time of an initial electrophysiology test. Two hundred thirty-five patients had one accessory AV connection and 15 patients had two or more. One hundred eighty-three accesso...
متن کاملHow well do we manage families with genetic problems?
I Wellens HJJ, Brugada P, Penn OC, Gorgels AP, Smeets J. Pre-excitation svndromes: clinical presentation, course and therapy. In: Zipes DP, Jalife J, eds. Cardiac electrophvsiology: from cell to bedside. Philadelphia: W B Saunders, 1990:691-702. 2 Klein GJ, Bashore TM, Sellers TD, Pritchett ELC, Smith WM, Gallagher JJ. Ventricular fibrillation in the Wolff-Parkinson-White syndrome. N Engl3' Med...
متن کاملCost of catheter versus surgical ablation in the Wolff-Parkinson-White syndrome.
In this retrospective study of 22 patients with the Wolff-Parkinson-White (WPW) syndrome, the cost of catheter ablation in 11 patients was compared with that of surgical ablation in another 11 patients. All patients in the catheter ablation group had a posteroseptal accessory pathway; in the surgical group, 5 patients had a left lateral accessory pathway, 3 had a left lateral and posteroseptal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 79 6 شماره
صفحات -
تاریخ انتشار 1989