Speckle-tracking strain of the left atrium: a transoesophageal echocardiographic validation study.
نویسندگان
چکیده
AIMS The aims of this study were (1) to evaluate the relationship between novel two-dimensional transthoracic indices of left atrial (LA) mechanical function (speckle-tracking- and tissue Doppler-derived parameters), conventional indices (A-wave peak velocity and velocity-time integral, and A' velocity), and transoesophageal echocardiographic parameters (LA appendage emptying velocity and spontaneous echocardiographic contrast); and (2) to assess to clinical feasibility of these novel transthoracic echocardiographic indices. METHODS AND RESULTS Transthoracic echocardiography was performed immediately prior to or following clinically indicated transoesophageal echocardiography in 100 individuals. Longitudinal reservoir LA strain, and reservoir, conduit, and atrial contractile strain rate were measured by both speckle-tracking and tissue Doppler approaches. Inter- and intra-observer variability in 20 randomly selected cases was evaluated by the Bland-Altman technique. The time required per analysis for these novel transthoracic echocardiographic indices was recorded. In relation to LA appendage emptying velocity, the respective absolute r-values for speckle-tracking reservoir strain, and reservoir, conduit, and atrial contractile strain rate were 0.53 (P < 0.001), 0.40 (P < 0.001), 0.21 (P = 0.05), and 0.61 (P < 0.001). The absolute r-values for tissue Doppler reservoir strain, and reservoir, conduit, and atrial contractile strain rate were 0.57 (P < 0.005), 0.53 (P < 0.001), 0.022 (P = 0.8), and 0.46 (P < 0.001), respectively. In contrast, the r-values for A-wave peak velocity and velocity-time integral, and A' velocity were 0.20 (P = 0.01), 0.26 (P = 0.05), and 0.35 (P = 0.007), respectively. Speckle-tracking-derived parameters achieved the greatest area-under-the-receiver-operating characteristic curve in the identification of moderate-severe LA spontaneous echocardigraphic contrast and were more rapidly measured (P < 0.001), while exhibiting similar reproducibility to tissue Doppler-derived measures. CONCLUSION Assessment of LA mechanical function using speckle-tracking echocardiography is a valid approach compared with transoesophageal echocardiography, and is clinically feasible.
منابع مشابه
Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملComparison of left atrial function in healthy individuals versus patients with non-ST-segment elevation myocardial infarction using two-dimensional speckle tracking echocardiography
Left atrial (LA) function has been associated with adverse outcomes in patients after acute myocardial infarction. The purpose of the current study was to evaluate LA function in patients with non-ST-segment elevation myocardial infarction (NSTEMI) by two-dimensional speckle tracking echocardiography (2D STE). Fifty-one patients with NSTEMI and 40 age-matched normal control individuals were enr...
متن کاملThree-dimensional transoesophageal echocardiography in detailed evaluation of cor triatriatum.
ment of left atrial appendage function with transthoracic tissue Doppler echocardiography. Eur J Echocardiogr 2009;10:363–71. 143. Inaba Y, Yuda S, Kobayashi N, Hashimoto A, Uno K, Nakata T et al. Strain rate imaging for noninvasive functional quantification of the left atrium: comparative studies in controls and patients with atrial fibrillation. J Am Soc Echocardiogr 2005; 18:729–36. 144. D’A...
متن کاملAssessment of Subclinical Myocardial Changes in Non-Alcoholic Fatty Liver Disease: A Case-Control Study Using Speckle Tracking Echocardiography
Background: Considering the association between cardiac abnormalities and non-alcoholic fatty liver disease (NAFLD), the present study aimed to evaluate the relationship between biopsy-proven NAFLD and functional echocardiographic parameters, including left ventricular (LV) global longitudinal strain (GLS) in asymptomatic individuals. Methods: Thirty asymptomatic patients with liver biopsy-prov...
متن کاملQuantification of left atrial strain and strain rate using cardiovascular magnetic resonance myocardial feature tracking
Background Cardiovascular Magnetic Resonance myocardial feature tracking (CMR-FT) is a quantitative technique tracking tissue voxel motion on standard steady-state free precession (SSFP) cine images to assess ventricular myocardial deformation. The importance of left atrial (LA) deformation assessment is increasingly recognized and can be assessed with echocardiographic speckle tracking. Howeve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 14 9 شماره
صفحات -
تاریخ انتشار 2013