Integrated FDG-PET/CT does not make invasive staging of the intrathoracic lymph nodes in non-small cell lung cancer redundant: a prospective study.
نویسندگان
چکیده
BACKGROUND Staging of non-small cell lung cancer (NSCLC) is important for determining choice of treatment and prognosis. The accuracy of FDG-PET scans for staging of lymph nodes is too low to replace invasive nodal staging. It is unknown whether the accuracy of integrated FDG-PET/CT scanning makes invasive staging redundant. METHODS In a prospective study, the mediastinal and/or hilar lymph nodes in patients with proven NSCLC were investigated with integrated FDG-PET/CT scanning. Pathological confirmation of all suspect lymph nodes was obtained to calculate the accuracy of the fusion images. In addition, the use of the standardised uptake value (SUV) in the staging of intrathoracic lymph nodes was analysed. RESULTS 105 intrathoracic lymph node stations from 52 patients with NSCLC were characterised. The prevalence of malignancy in the lymph nodes was 36%. The sensitivity of the integrated FDG-PET/CT scan to detect malignant lymph nodes was 84% and its specificity was 85% (positive likelihood ratio 5.64, negative likelihood ratio 0.19). SUV(max), SUV(mean) and the SUV(max)/SUV(liver) ratio were all significantly higher in malignant than in benign lymph nodes. The area under the receiver operating curve did not differ between these three quantitative variables, but the highest accuracy was found with the SUV(max)/SUV(liver) ratio. At a cut-off value of 1.5 for the SUV(max)/SUV(liver )ratio, the sensitivity and specificity to detect malignant lymph node invasion were 82% and 93%, respectively. CONCLUSION The accuracy of integrated FDG-PET/CT scanning is too low to replace invasive intrathoracic lymph node staging in patients with NSCLC. The visual interpretation of the fusion images of the integrated FDG-PET/CT scan can be replaced by the quantitative variable SUV(max)/SUV(liver) without loss of accuracy for intrathoracic lymph node staging.
منابع مشابه
LUNG CANCER Integrated FDG-PET/CT does not make invasive staging of the intrathoracic lymph nodes in non-small cell lung cancer redundant: a prospective study
Background: Staging of non-small cell lung cancer (NSCLC) is important for determining choice of treatment and prognosis. The accuracy of FDG-PET scans for staging of lymph nodes is too low to replace invasive nodal staging. It is unknown whether the accuracy of integrated FDG-PET/CT scanning makes invasive staging redundant. Methods: In a prospective study, the mediastinal and/or hilar lymph n...
متن کاملA Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.
Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...
متن کاملMediastinal staging in non-small-cell lung carcinoma: computed tomography versus F-18-fluorodeoxyglucose positron-emission tomography and computed tomography
BACKGROUND After the diagnosis Non-Small-Cell Lung Carcinoma (NSCLC) has been established, consideration must turn toward the stage of disease, because this will impact directly on management and prognosis. Staging is used to predict survival and to guide the patient toward the most appropriate treatment regimen or clinical trial. Distinguishing malignant involvement of the mediastinal lymph no...
متن کاملTriage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer
Objective(s): Small cell lung cancer (SCLC) is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM) staging of SCLC, compared to the conventional computed tomography (CT) scan and its potential role as a prognosticat...
متن کاملMediastinal lymph node sampling following positron emission tomography with fluorodeoxyglucose imaging in lung cancer staging.
OBJECTIVES To evaluate the predictive accuracy as well as the rates of false-positive and false-negative results of CT and positron emission tomography (PET)-fluorodeoxyglucose (FDG) imaging in detecting the metastatic intrathoracic lymph nodes in patients with suspected or proven non-small cell lung cancer (NSCLC). Our other objective was to determine the need for routine invasive sampling pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thorax
دوره 62 8 شماره
صفحات -
تاریخ انتشار 2007