Computed-tomography imaging spectrometer: experimental calibration and reconstruction results.
نویسندگان
چکیده
A temporally and spatially nonscanning imaging spectrometer is described in terms of computedtomography concepts, specifically the central-slice theorem. A sequence of three transmission sinusoidalphase gratings rotated in 60° increments achieves dispersion in multiple directions and into multiple orders. The dispersed images of the system's field stop are interpreted as two-dimensional projections of a three-dimensional (x, y, λ) object cube. Because of the size of the finite focal-plane array, this imaging spectrometer is an example of a limited-view-angle tomographic system. The imaging spectrometer's point spread function is measured experimentally as a function of wavelength and position in the field of view. Reconstruction of the object cube is then achieved through the maximum-likelihood, expectation-maximization algorithm under the assumption of a Poisson likelihood law. Experimental results indicate that the instrument performs well in the case of broadband and narrow-band emitters.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملMWIR Snapshot Imaging Spectrometer: Calibration and Imaging Experiments; Complete Imaging Stokes Polarimeter for the 3-5 um Spectral Band
We report results of experimentation with a new, high-resolution MWIR non-scanning, snapshot imaging spectrometer capable of simultaneously recording spatial and spectral data from a rapidly varying target scene. The instrument is based on computed tomography concepts and operates in a midwave infrared band of 3.0 to 5.0 μm. High speed spectral imaging was demonstrated by collecting spectro-spa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 34 22 شماره
صفحات -
تاریخ انتشار 1995