Clinical use of the volume-time curve for endotracheal tube cuff management.

نویسندگان

  • Douglas Willian Bolzan
  • Walter Jose Gomes
  • Thatiana Cristina Alves Peixoto
  • Sônia Maria Faresin
  • Antônio Carlos de Camargo Carvalho
  • Angelo Amato Vincenzo De Paola
  • Solange Guizilini
چکیده

BACKGROUND Previous investigation showed that the volume-time curve technique could be an alternative for endotracheal tube (ETT) cuff management. However, the clinical impact of the volume-time curve application has not been documented. The purpose of this study was to compare the occurrence and intensity of a sore throat, cough, thoracic pain, and pulmonary function between these 2 techniques for ETT cuff management: volume-time curve technique versus minimal occlusive volume (MOV) technique after coronary artery bypass grafting. METHODS A total of 450 subjects were randomized into 2 groups for cuff management after intubation: MOV group (n = 222) and volume-time curve group (n = 228). We measured cuff pressure before extubation. We performed spirometry 24 h before and after surgery. We graded sore throat and cough according to a 4-point scale at 1, 24, 72, and 120 h after extubation and assessed thoracic pain at 24 h after extubation and quantified the level of pain by a 10-point scale. RESULTS The volume-time curve group presented significantly lower cuff pressure (30.9 ± 2.8 vs 37.7 ± 3.4 cm H2O), less incidence and intensity of sore throat (1 h, 23.7 vs 51.4%; and 24 h, 18.9 vs 40.5%, P < .001), cough (1 h, 19.3 vs 48.6%; and 24 h, 18.4 vs 42.3%, P < .001), thoracic pain (5.2 ± 1.8 vs 7.1 ± 1.7), better preservation of FVC (49.5 ± 9.9 vs 41.8 ± 12.9%, P = .005), and FEV1 (46.6 ± 1.8 vs 38.6 ± 1.4%, P = .005) compared with the MOV group. CONCLUSIONS The subjects who received the volume-time curve technique for ETT cuff management presented a significantly lower incidence and severity of sore throat and cough, less thoracic pain, and minimally impaired pulmonary function than those subjects who received the MOV technique during the first 24 h after coronary artery bypass grafting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume-time curve: an alternative for endotracheal tube cuff management.

BACKGROUND Despite numerous studies on endotracheal tube cuff pressure (CP) management, the literature has yet to establish a technique capable of adequately filling the cuff with an appropriate volume of air while generating low CP in a less subjective way. The purpose of this prospective study was to evaluate and compare the CP levels and air volume required to fill the endotracheal tubes cuf...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Effect of Positioning on the Pressure of Endotracheal Tube Cuff Filled with Air versus Saline: A Double-blind Randomized Clinical Trial

Background: Control and maintenance of endotracheal tube cuff pressure and prevention of sore throat are major concerns in post-anesthesia care. Aim: This study aimed to evaluate changes in the pressure of the endotracheal tube cuff filled with saline versus air and post-anesthesia sore throat when the position is altered from supine to lateral. <st...

متن کامل

Safe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review

Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 11  شماره 

صفحات  -

تاریخ انتشار 2014