WE-E-BRB-05: A Novel Detector Dose Calculation Model for in Vivo Delivery Verification of IMRT Treatments.

نویسندگان

  • W Lu
  • M Chen
  • G Olivera
  • D Galmarini
چکیده

PURPOSE Exit 2D detectors are widely used in clinics as a tool for pre- treatment field verification. It is desired to have accurate modeling of the detector dose for each IMRT plan with patient geometry for in-vivo delivery verification. We propose a novel hybrid of model and measurement based methods to estimate the detector dose using the information from TPS and plan/verification CT. METHODS Our approach is based on the generalized equivalent field size (GEFS) method. It requires two commissioning tables for various square fields (l×l, 2×2, …40×40): the percent depth dose (PDD) table and the detector correction factor (DDCF) table. PDDs are retrieved from the treatment planning system (TPS), and DDCFs are reconstructed from measurement with various field sizes and air gaps (from 5 cm to 50 cm). GEFS models the detector point dose as the superposition of annular contribution of the fluence map, which is retrieved from the TPS. Correction on the radiological path length is calculated through ray-tracing the patient CT. Corrections on the air gap between the couch and detector and detector response are applied via table lookup on PDD and DDCF. RESULTS We validated the proposed method using TPS with extended geometry and direct clinic measurements for both regular and IMRT fields, various phantom and patient geometry. For all calculations, more than 98% of pixels pass the gamma index with criteria of 3%, 3mm. Each calculation took only a few seconds on a single PC. CONCLUSIONS We proposed a novel detector dose calculation method that can be applied for arbitrary IMRT field and arbitrary patient geometry. The calculation is simple and fast and when compared with detector measurement during IMRT treatment, makes in- vivo delivery verification and dose reconstruction feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

The use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique

Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part27  شماره 

صفحات  -

تاریخ انتشار 2012