Evaluation of conventional and real-time PCR assays using two targets for confirmation of results of the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae test for detection of Neisseria gonorrhoeae in clinical samples.
نویسندگان
چکیده
Two conventional PCR-enzyme immunoassays (PCR-EIAs) and two real-time PCR assays (LightCycler system; Roche Diagnostics) were evaluated as confirmation assays with cppB and 16S rRNA genes as targets. Of 765 male and female genitourinary and nasopharyngeal specimens positive for Neisseria gonorrhoeae in the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR test (Roche Diagnostics), 229 (30%) were confirmed positive; 13 of these (5.7%) were lacking the cppB gene. Of the 534 samples (70%) that could not be confirmed, 81 (15%) showed a positive crossing point. However, melting curve analysis revealed an aberrant melting temperature in the LightCycler 16S rRNA assay; therefore, these samples were considered non-N. gonorrhoeae Neisseria species. Both of the 16S rRNA assays performed well, with positive predictive values of 99.1% and 100% for the PCR-EIAs and the real-time assays, respectively, and a negative predictive value of 99.8% for both. The cppB assays were compromised by the absence of the cppB gene in 5.7% of the N. gonorrhoeae-positive samples, resulting in negative predictive values of 96.8% and 97.6% for the PCR-EIAs and the real-time assays, respectively. Therefore, the 16S rRNA gene is preferable to the cppB gene as a target for confirmation assays. The melting curve analysis of the real-time assays provides useful additional information.
منابع مشابه
Neisseria species identification assay for the confirmation of Neisseria gonorrhoeae-positive results of the COBAS Amplicor PCR.
Screening assays for Neisseria gonorrhoeae exhibit low positive predictive values, particularly in low-prevalence populations. A new real-time PCR assay that detects and identifies individual Neisseria spp. using melt curve analysis was compared to two previously published supplementary assays. NsppID, a 16S rRNA real-time PCR/melt curve assay developed to distinguish N. gonorrhoeae from other ...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملValidation of a laboratory-developed real-time PCR protocol for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.
OBJECTIVE To evaluate a sensitive and specific, real-time PCR assay with internal control for Chlamydia trachomatis and Neisseria gonorrhoeae DNA detection in urine specimens. METHODS The diagnostic performance of a laboratory-developed quadruplex assay (LDQA) targeting the cryptic plasmid and MOMP genes of C trachomatis, the porA pseudogene of N gonorrhoeae and a synthetic internal control w...
متن کاملEvaluation of COBAS AMPLICOR (Roche): accuracy in detection of Chlamydia trachomatis and Neisseria gonorrhoeae by coamplification of endocervical specimens.
We evaluated further the accuracy of the COBAS AMPLICOR (Roche) (CA) PCR-based system in detection of Chlamydia trachomatis and Neisseria gonorrhoeae in endocervical specimens. Endocervical specimens collected for any indication for testing for C. trachomatis and N. gonorrhoeae among a university hospital health system population were included. Testing for C. trachomatis was done by two PCR met...
متن کاملEvaluation of real time polymerase chain reaction assays for confirmation of Neisseria gonorrhoeae in clinical samples tested positive in the Roche Cobas Amplicor assay.
OBJECTIVE Development of a rapid, sensitive, and accurate assay for confirmation of Neisseria gonorrhoeae in clinical samples. METHOD Two real time polymerase chain reaction (PCR) assays, developed on the LightCycler for amplification of the N gonorrhoeae cppB gene, were utilised for confirmation of this bacterial pathogen in samples positive by the Roche Cobas Amplicor assay. Performance cha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 43 5 شماره
صفحات -
تاریخ انتشار 2005