Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach.

نویسندگان

  • D Keane
  • J Haase
  • C J Slager
  • E Montauban van Swijndregt
  • K G Lehmann
  • Y Ozaki
  • C di Mario
  • R Kirkeeide
  • P W Serruys
چکیده

BACKGROUND Computerized quantitative coronary angiography (QCA) has fundamentally altered our approach to the assessment of coronary interventional techniques and strategies aimed at the prevention of recurrence and progression of stenosis. It is essential, therefore, that the performance of QCA systems, upon which much of our scientific understanding has become integrally dependent, is evaluated in an objective and uniform manner. METHODS AND RESULTS We validated 10 QCA systems at core laboratories in North America and Europe. Cine films were made of phantom stenoses of known diameter (0.5 to 1.9 mm) under four experimental conditions: in vivo (coronary arteries of pigs) calibrated at the isocenter or by use of the catheter as a scaling device and in vitro with 50% contrast and 100% contrast. The cine films were analyzed by each automated QCA system without observer interaction. Accuracy and precision were taken as the mean and SD of the signed differences between the phantom stenoses, and the measured minimal luminal diameters and the correlation coefficient (r), the SEE, the y intercept, and the slope were derived by their linear regression. Performance of the 10 QCA systems ranged widely: accuracy, +0.07 to +0.31 mm; precision, +/- 0.14 to +/- 0.24 mm; correlation (r), .96 to .89; SEE, +/- 0.11 to +/- 0.16 mm; intercept, +0.08 to +0.31 mm; and slope, 0.86 to 0.64. CONCLUSIONS There is a marked variability in performance between systems when assessed over the range of 0.5 to 1.9 mm. The range of accuracy, intercept, and slope values of this report indicates that absolute measurements of luminal diameter from different multicenter angiographic trials may not be directly comparable and additionally suggests that such absolute measurements may not be directly applicable to clinical practice using an on-line QCA system with a different edge detection algorithm. Power calculations and study design of angiographic trials should be adjusted for the precision of the QCA system used to avoid the risk of failing to detect small differences in patient populations. This study may guide the fine-tuning of algorithms incorporated within each system and facilitate the maintenance of high standards of QCA for scientific studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative review of various interventional methods for coronary angiography and angioplasty

Background and Objective: Coronary artery disease (CAD) is one of the most common diseases today. Among the diagnostic methods, angiography is the main and gold standard in the diagnosis Since angiography is an invasive procedure, this procedure complications range widely from minor problems with short term sequelae to life threatening ones may cause irreversible damage or even death. Materials...

متن کامل

Quantitative Coronary Angiography in the Interventional Cardiology

Coronary angiography through selective injection of radiopaque contrast agent into the coronary arteries is currently the gold standard for evaluating coronary artery disease (CAD). Subjective visual estimation of lesion severity has been shown to be inadequate due to high degrees of intraobserver and interobserver variability (Topol & Nissen, 1995). Since the late 1980s methods and algorithms ...

متن کامل

Effect of Benson’s relaxation technique on the anxiety of patients undergoing coronary angiography: A randomized control trial

Background and Purpose: Anxiety is a common problem associated with invasive medical procedures, especially in patients undergoing coronary angiography. As an intensifier at cardiovascular reactions, anxiety poses significant risk to the health of patients undergoing angiography. Researchers believe that use of Benson’s relaxation technique could reduce anxiety in different patients. Th...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 91 8  شماره 

صفحات  -

تاریخ انتشار 1995