Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures.

نویسندگان

  • H C Uğur
  • A Attar
  • A Uz
  • I Tekdemir
  • N Egemen
  • S Cağlar
  • Y Genç
چکیده

OBJECTIVE Although several clinical applications of transpedicular screw fixation in the cervical spine have been documented recently, few anatomic studies concerning the cervical pedicle are available. This study was designed to evaluate the anatomy and adjacent neural relationships of the middle and lower cervical pedicle (C3-C7). The main objective is to provide accurate information for transpedicular screw fixation in the cervical region and to minimize complications by providing a three-dimensional orientation. METHODS Twenty cadavers were used to observe the cervical pedicle and its relationships. After removal of the posterior bony elements, including spinous processes, laminae, lateral masses, and inferior and superior facets, the isthmus of the pedicle was exposed. Pedicle width, pedicle height, interpedicular distance, pedicle-inferior nerve root distance, pedicle-superior nerve root distance, pedicle-dural sac distance, medial pedicle-dural sac distance, mean angle of the pedicle, root exit angle, and nerve root diameter were measured. RESULTS The results indicate that there was no distance between the pedicle and the superior nerve root and between the pedicle and the dural sac in 16 specimens, whereas there was a slight distance in the lower cervical region in the 4 other specimens. The mean distance between the pedicle and the inferior nerve root for all specimens ranged from 1.0 to 2.5 mm. The mean distance between the medial pedicle and the dural sac increased consistently from 2.4 to 3.1 mm. At C3-C7, the mean pedicle height ranged from 5.2 to 8.5 mm, and the mean pedicle width ranged from 3.7 to 6.5 mm. Interpedicular distance ranged from 21.2 to 23.2 mm. The mean root exit angle ranged from 69 to 104 degrees, with the largest angle at C3 and the smallest at C6. The mean angle of the pedicle ranged from 38 to 48 degrees. The nerve root diameter increased consistently from 2.7 mm at C3 to 3.8 mm at C6 and then decreased to 3.7 mm at the C7 level. Differences in measurements were considered statistically significant at levels ranging from P < 0.05 to P < 0.01. CONCLUSION This study indicates that improper placement of the pedicle screw medially and superiorly in the middle and lower cervical spine should be avoided and that the anatomic variations between individuals should be established by measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior Fixation Techniques in the Subaxial Cervical Spine

This article reviews the historical context, indications, techniques, and complications of four posterior fixation techniques to stabilize the subaxial cervical spine. Specifically, posterior wiring, laminar screw fixation, lateral mass fixation, and pedicle screw fixation are among the common methods of operative fixation of the subaxial cervical spine. While wiring and laminar screw fixation ...

متن کامل

Cervical Pedicle Screw Fixation: Anatomic Feasibility of Pedicle Morphology and Radiologic Evaluation of the Anatomical Measurements

STUDY DESIGN All parameters were measured manually and with a computed tomography (CT) scanner. For the manual measurements, a Vernier scale instrument was used. PURPOSE This study evaluates quantitatively pedicles of middle and lower cervical spine (C3 to C7) and to evaluate the possibilities of using these structures as anchors in posterior cervical fusion. OVERVIEW OF LITERATURE Pedicle ...

متن کامل

Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.

STUDY DESIGN Prospective clinical study with postoperative radiologic control of pedicle screw placement in the cervical spine. OBJECTIVES To evaluate whether cervical pedicle screws can be placed safely in a conventional technique when using cannulated screws and separate stab incisions. Also, to evaluate if accuracy and safety of pedicle screw placement can be improved using a computer-assi...

متن کامل

Anatomic Characteristics of Mental Foramen and Anterior Loop of Mandibular Canal in a population of South IRAN : a cone-beam computed tomography study

Introduction: Regarding the anatomic variety in the anterior mandible it is necessary to obtain adequate information about the vital structures in this area to protect them in dental surgeries and preventing injuries that might occur afterwards. The aim of this study is to describe anatomic characteristics of mental foramen and anterior loop on CBCT images.  Materials and Methods: On CBCT imag...

متن کامل

Surgical anatomy of the uncinate process and transverse foramen determined by computer tomography

Surgical anatomy of the uncinate process and transverse foramen determined by computer tomography. Keywords ► cervical spine ► uncinate process ► transverse foramen ► intervertebral foramen ► decompression Abstract Study Design Computed tomography–based cohort study. Objective Although there are publications concerning the relationship between the vertebral artery and uncinate process, there is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurosurgery

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2000