Enhancement of Dynamic Stability and Voltage Control of a Grid- Connected Offshore Wind Farm and Marine- Current Farm Using a Statcom

نویسندگان

  • T. RADHA
  • M. SHOBHA
  • B. NARENDRA
  • K. SWETHA
چکیده

1PG Scholar, MTECH (PE), CVRT, Andhrapradesh, India 2Associate Professor & HOD, Dept of EEE, CVRT, Andhrapradesh, India 3,4Assistant Professor, Dept of EEE, Andhrapradesh, India ---------------------------------------------------------------------***--------------------------------------------------------------------Abstract: This venture shows a control plot in view of a static synchronous compensator (STATCOM) to accomplish both voltage control and damping improvement of a gridassociated incorporated 80-MW offshore wind farm (OWF) and 40-MW marine-current farm (MCF). The execution of the contemplated OWF is reproduced by an equal doubly-fed induction generator (DFIG) driven by a proportional wind turbine (WT) while a comparable squirrel-confine rotor induction generator (SCIG) driven by an equal marinecurrent turbine (MCT) is utilized to recreate the qualities of the MCF. A damping controller of the STATCOM is planned by utilizing modular control hypothesis to contribute powerful damping attributes to the considered system under various working conditions. A frequency-area approach in view of a changed system display utilizing Eigen esteem strategies and a period space plot in view of a nonlinear system show subject to different unsettling influences are both utilized to reenact the adequacy of the proposed control conspire. It can be finished up from the reproduced comes about that the proposed STATCOM joined with the outlined damping controller is extremely successful to settle the contemplated system under aggravation conditions. The voltage fluctuations of the AC bus subject to the dynamic power varieties of the contemplated system can likewise be viably controlled by the proposed control plot.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Stability Improvement of an Integrated Grid- Connected DFIG based Offshore Wind Farm and SCIG Marine- Current Farm Using a STATCOM

Here in this paper presents a control strategy based on a static synchronous compensator (STATCOM) obtain both voltage control and damping enhancement of grid connected integrated 80 MW offshore wind form (OWF) and 40 MW marine current farm (MCF). The demonstration of the investigated Offshore Wind Farm is simulated by an equivalent wind turbine (WT) while an equivalent squirrel cage rotor indu...

متن کامل

A Novel control scheme for a Grid Connected Wind-Farm and Marine-Current Farm Using a STATCOM

This paper presents a control scheme based on a static synchronous compensator (STATCOM) to achieve both voltage control and damping enhancement of a grid-connected integrated 80-MW offshore wind farm (OWF) and 40-MW marine-current farm (MCF). The performance of the studied OWF is simulated by an equivalent doubly-fed induction generator (DFIG) driven by an equivalent wind turbine (WT) while an...

متن کامل

Dynamic Performance Analysis of DFIG based Wind Farm with STATCOM and SVC

To meet the strict criteria of grid codes for the integrated wind farm with the grid has become a major point of concern for engineers and researchers today. Moreover voltage stability is a key factor for the stable operation of grid connected wind farm during fault ride through and grid disturbances. This paper investigates the implementation and comparison of FACTS devices like STATCOM and SV...

متن کامل

Unbalanced Grid Faults Ride By StatCom Control at Fixed Speed Induction Generator Wind Farm

Fixed speed induction generator (FSIG) having high asymmetrical fault percentage than variable speed. Even though there are different ways to control these faults StatCom control method to compensate reactive power is one of the useful and highly beneficial method. In this paper the FSIG wind farm is observed under unbalanced grid fault with StatCom connected to it with the help of MATLAB simul...

متن کامل

Improving the Voltage Profile of the Power System Using PV-STATCOM

This paper presents a novel concept of utilizing the photo voltaic solar farm inverter as STATCOM(Static Compensator), named PV-STATCOM, in order to improve the voltage profile of the power system. The entire STATCOM is able to transmit either active or reactive power into the grid. This system is connected to a 14 BUS IEEE standard grid as a case study to simulate the performance of the system...