Reference curve of the fetal ventricular septum area by the STIC method: preliminary study.

نویسندگان

  • Liliam Cristine Rolo
  • Luciano Marcondes Machado Nardozza
  • Edward Araujo Júnior
  • Christiane Simioni
  • Marina Maccagnano Zamith
  • Antonio Fernandes Moron
چکیده

BACKGROUND Early detection of septal changes such as septal hypertrophy commonly present in fetuses of diabetic mothers would help reduce the high rates of infant mortality. OBJECTIVE Determine reference ranges for the fetal ventricular septal area through three-dimensional ultrasound (US3D) using the STIC method (Spatio-Temporal Image Correlation). METHODS We conducted a cross-sectional study with 69 pregnant women between the 18th and 33rd weeks of pregnancy. We used as a reference the four-chamber plane with the ROI (Region of Interest) positioned from the ventricles; the septum area were manually marked. To assess the correlation of the interventricular septum area with gestational age (GA), we constructed scatter plots and calculated Pearson's correlation coefficient (r), and the adjustment was performed by the coefficient of determination (R²). We calculated averages, medians, standard deviations (sd), as well as maximum and minimum values. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC). The interventricular septum thickness was measured and it was correlated with gestational age and the septal area rendered in 52 patients using the ICC. RESULTS The interventricular septum area was highly correlated with gestational age (r = 0.81), and the average increased from 0.47 cm² in the 18th week to 2.42 cm² in the 33rd of gestation. The intraobserver reproducibility was excellent with ICC = 0.994. No significant correlation was observed between the interventricular septum measurement and the GA (R² = 0.200), as well as there was no correlation with the septal area rendered with ICC = 0.150. CONCLUSION Reference intervals for the interventricular septum area between the 18th and the 33rd pregnancy week were determined to be highly reproducible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Feasibility Study on Prenatal Cardiac Screening Using Four-Dimensional Ultrasound with Spatiotemporal Image Correlation: A Multicenter Study

OBJECTIVE This study aimed at investigating the feasibility of using the spatiotemporal image correlation (STIC) technology for prenatal cardiac screening, finding factors that influence the offline evaluation of reconstructed fetal heart, and establishing an optimal acquisition scheme. METHODS The study included 452 gravidae presenting for routine screening at 3 maternity centers at 20-38 ge...

متن کامل

Three-dimensional ultrasound STIC-HDlive rendering: new technique to assessing of fetal heart

Congenital heart diseases (CHD) are the most common fetal congenital malformations, corresponding to an incidence six higher than chromosome anomalies and four higher than neural tube defects [1]. The prevalence of CHD in newborns ranges from 0.6% to 5% [2]. It's too known that the prenatal diagnosis can modify the outcome of some types of CHD [3,4]. The two-dimensional echocardiography is the ...

متن کامل

Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart.

OBJECTIVE To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. METHODS We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate th...

متن کامل

Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images

Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 96 5  شماره 

صفحات  -

تاریخ انتشار 2011