Appropriate tube size selection based on radiological images

نویسنده

  • Hee-Pyoung Park
چکیده

Corresponding author: Hee-Pyoung Park, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101, Daehak-ro, Jongno-gu, Seoul 110-744, Korea. Tel: 82-2-2072-2466, Fax: 82-2-747-5639, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

Ultrasound assessment of subglottic region for estimation of appropriate endotracheal tube size in pediatric anesthesia

BACKGROUND AND AIMS Endotracheal tube (ETT) selection in pediatric patients is mainly done with the age, height, or weight-based formula. We compared ultrasound assessment of the subglottic area to predict the outer diameter of the ETT, with that of modified Cole's formula. The aim of the study is to compare the appropriateness of uncuffed ETT selection based on modified Cole's formula with tha...

متن کامل

Evaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function

Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...

متن کامل

Pediatric endotracheal tube selection: a comparison of age-based and height-based criteria.

Many methods are taught and used clinically to determine what size uncuffed endotracheal tube is required for the pediatric patient. The purpose of this study was to compare the effectiveness of two methods of selection used clinically: (1) the traditional age-based (AB) formula; (age in years +16) divided by 4, and (2) the method based on body length using the Broselow pediatric resuscitation ...

متن کامل

Selection of an Appropriate Left-sided Double-lumen Tube Size for One-lung Ventilation among Asians

CONTEXT Selecting an appropriate size double-lumen tube (DLT) for one-lung ventilation has always been a challenge as most choose it based on experience or using the existing guidelines based on gender and height. AIMS The aim of this study was to determine if the appropriate choice of this tube could be based on the patients' height, weight, tracheal diameter (TD), or the left main stem bron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2014