Three-dimensional multiexcitation magnetoacoustic tomography with magnetic induction.
نویسندگان
چکیده
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a hybrid imaging modality proposed to image electrical conductivity contrast of biological tissue with high spatial resolution. This modality combines magnetic excitations with ultrasound detection through the Lorentz force based coupling mechanism. However, previous studies have shown that MAT-MI method with single type of magnetic excitation can only reconstruct the conductivity boundaries of a sample. In order to achieve more complete conductivity contrast reconstruction, we proposed a multiexcitation MAT-MI approach. In this approach, multiple magnetic excitations using different coil configurations are applied to the object sequentially and ultrasonic signals corresponding to each excitation are collected for conductivity image reconstruction. In this study, we validate the new multiexcitation MAT-MI method for three-dimensional (3D) conductivity imaging through both computer simulations and phantom experiments. 3D volume data are obtained by utilizing acoustic focusing and cylindrical scanning under each magnetic excitation. It is shown in our simulation and experiment results that with a common ultrasound probe that has limited bandwidth we are able to correctly reconstruct the 3D relative conductivity contrast of the imaging object. As compared to those conductivity boundary images generated by previous single-excitation MAT-MI, the new multiexcitation MAT-MI method provides more complete conductivity contrast reconstruction, and therefore, more valuable information in possible clinical and research applications.
منابع مشابه
The Effect of Electrical Anisotropy and Acoustic Inhomogeneity in Magnetoacoustic Tomography with Magnetic Induction
Magnetoacoustic tomography with magnetic induction(MAT-MI) is a noninvasive technology for imaging the distribution of electrical impedance in biological tissue. In the sameple, a time-varying magnetic field induces currents. A static magnetic field interact with the currents to produce a Lorentz force. Consequently, the sample will emit ultrasonic waves by the Lorentz force. The objective of t...
متن کاملMathematical models and reconstruction methods in magneto-acoustic imaging
In this paper, we provide the mathematical basis for three different magnetoacoustic imaging approaches (vibration potential tomography, magneto-acoustic tomography with magnetic induction, and magneto-acoustic current imaging) and propose new algorithms for solving the inverse problem for each of them.
متن کاملNumerical Study of Magnetoacoustic Signal Generation with Magnetic Induction Based on Inhomogeneous Conductivity Anisotropy
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a noninvasive imaging modality for generating electrical conductivity images of biological tissues with high spatial resolution. In this paper, we create a numerical model, including a permanent magnet, a coil, and a two-layer coaxial cylinder with anisotropic electrical conductivities, for the MAT-MI forward problem. We analyze the...
متن کاملMulti-excitation magnetoacoustic tomography with magnetic induction (MAT-MI)
Magnetoacoustic tomography with magnetic induction (MAT-MI) is an approach proposed to do non-invasive electrical conductivity imaging of biological tissue using magnetic induction and ultrasound measurements. In the present study, based on the analysis of the relationship between the conductivity distribution and the generated MAT-MI acoustic source, we propose a new multi-excitation algorithm...
متن کاملMagnetoacoustic Tomography with Magnetic Stimulation (MAT-MS)
We have proposed a new imaging modality, magnetoacoustic tomography with magnetic stimulation (MAT-MS) to image the electrical impedance distribution. In this paper we report out pilot experimental study. In MAT-MS, the tissue is put in a static magnetic field and a pulsed ( s μ ) magnetic field. The pulsed magnetic field induces eddy current in the tissue. Consequently, the tissue will emit ul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physics
دوره 108 12 شماره
صفحات -
تاریخ انتشار 2010