Polyacrylamide-based monolithic capillary column with coating of cellulose tris(3,5-dimethylphenyl-carbamate) for enantiomer separation in capillary electrochromatography.

نویسندگان

  • Xiaoli Dong
  • Ren'an Wu
  • Jing Dong
  • Minghuo Wu
  • Yan Zhu
  • Hanfa Zou
چکیده

A hydrophilic chiral capillary monolithic column for enantiomer separation in CEC was prepared by coating cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) on porous hydrophilic poly(acrylamide-co-N,N'-methylene-bisacrylamide) (poly(AA-co-MBA)) monolithic matrix with confine of a fused-silica capillary. The coating conditions were optimized to obtain a stable and reproducible chiral stationary phase for CEC. The effect of organic modifier of ACN in aqueous mobile phase for the enantiomer separation by CEC was investigated, and the significant influence of ACN on the enantioresolution and electrochromatographic retention was observed. Twelve pairs of enantiomers including acidic, neutral, and basic analytes were tested and nine pairs of them were baseline-enantioresolved with acidic and basic aqueous mobile phases. A good within-column repeatability in retention time (RSD = 2.4%) and resolution (RSD = 3.2%) was obtained by consecutive injections of a neutral compound, benzoin, on a prepared chiral monolithic column, while the between-column repeatability in retention time (RSD = 6.4%) and resolution (RSD = 9.6%) was observed by column-to-column examination. The prepared monolithic stationary phase showed good stability in either acidic or basic mobile phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monolithic silica capillary column with coated cellulose tris(3,5-dimethylphenylcarbamate) for capillary electrochromatographic separation of enantiomers.

Monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 microm and were modified by coating of cellulose tris(3,5-dimethylphenylcarbamate). Influences of the factors in the modification process on enantiomer separations were investigated. The prepared columns were used to perform enantiomer separations by CEC. Fifteen and t...

متن کامل

Chiral separation of binaphthol enantiomers on molecularly imprinted polymer monolith by capillary electrochromatography.

A novel enantioseparational monolithic stationary phase for binaphthol based on a molecular imprinting method was introduced and evaluated in capillary electrochromatography (CEC). The monolithic stationary was prepared by the in situ copolymerization of methacrylic acid and ethylene glycol dimethacrylate in a porogenic solvent (toluene or toluene-isooctane) in the presence of an imprinting mol...

متن کامل

Preparation of a positively charged cellulose derivative chiral stationary phase with copolymerization reaction for capillary electrochromatographic separation of enantiomers.

A positively charged chiral stationary phase (CSP) was prepared by chemically immobilizing cellulose 3,5-dimethylphenylcarbamate onto methacryloyldiethylenetriaminopropylated silica (MCDEAPS) via a radical copolymerization reaction. The prepared CSP was evaluated for enantiomer separation in nonaqueous capillary electrochromatography (CEC). Electroosmotic flow (EOF) generated on the prepared CS...

متن کامل

Enantiomeric Separation and Circular Dichroism Detection of Metalaxyl Acid Metabolite by Chiral High Performance Liquid Chromatography

The enantiomers of metalaxyl acid metabolite (MX-acid) were separated by HPLC using cellulose-tris-(3,5-dimethylphenyl-carbamate) (CDMPC) as chiral stationary phase. The effects of mobile phase composition, flow rate and column temperature on the resolution were investigated and good separation was achieved with n-hexane/2-propanol/trifluoroacetic acid as mobile phase. The circular dichroisms d...

متن کامل

Enantiomer separation by capillary electrochromatography using fritless packed columns.

This review summarizes recent developments in the field of enantiomer separation by capillary electrochromatography using fritless packed columns. Various enantiomers have been separated by employing fritless packed columns prepared in a fused silica capillary either by the immobilization of chiral packing materials by sintering or sol-gel technology or by in situ polymerization of a mixture co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2008