Cannulating in haemodialysis: rope-ladder or buttonhole technique?
نویسندگان
چکیده
BACKGROUND The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is preferably executed by a 'single-sticker'. This study was conducted to compare these cannulation techniques using objective parameters. METHODS We introduced the buttonhole technique for self-cannulating home haemodialysis patients and compared it with baseline data obtained with the rope-ladder technique. Thirty-three patients with a native arteriovenous fistula were observed prospectively during 18 months on the following parameters: cannulating ease, number of bad sticks, pain, time of compression after cannula removal, bleeding, infectious complications and aneurysm formation. RESULTS With the buttonhole method, cannulating ease improved distinctly, which was especially favourable in patients with a short fistula vein. Reported cannulation pain did not change significantly. The incidence of bad sticks decreased significantly, as well as time of compression after cannula removal, without increased incidence of bleeding. Three patients developed a local skin infection of their buttonhole during the study, after which the disinfection routine prior to cannulation was changed. CONCLUSIONS Compared with the rope-ladder technique, the buttonhole method offers the advantage of an easier cannulation procedure with less bad sticks, which has a special benefit for patients with limited access cannulation sites or with a fistula which is difficult to cannulate. Prolonged compression times or re-bleeding episodes did not occur, but precautions have to be taken in order to prevent infectious complications. The buttonhole method can contribute considerably to the cannulating ease of self-cannulating patients, thus providing a better quality of life.
منابع مشابه
Arterio-venous fistula buttonhole cannulation technique: a retrospective analysis of infectious complications
BACKGROUND There are two main methods of accessing arterio-venous fistulas (AVFs); the 'buttonhole' and the 'rope-ladder' cannulation technique. Several small studies have hypothesized that the buttonhole technique is associated with increased rates of fistula-associated infection. This study addresses this hypothesis. METHODS A retrospective review of all patients attending a large outpatien...
متن کاملButtonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.
BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...
متن کاملButtonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
BACKGROUND The rope-ladder puncture technique, with cannulation along the whole length of the vessel traject, has been very common in haemodialysis patients with autogenous arterio-venous fistula (AVF). Today's dialysis population with AVF may exhibit difficult cannulation, because of a short vein length or a complicated cannulation route. An alternative needling possibility is the buttonhole (...
متن کاملButtonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.
BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, a...
متن کاملCannulation technique influences arteriovenous fistula and graft survival
Hemodialysis patient survival is dependent on the availability of a reliable vascular access. In clinical practice, procedures for vascular access cannulation vary from clinic to clinic. We investigated the impact of cannulation technique on arteriovenous fistula and graft survival. Based on an April 2009 cross-sectional survey of vascular access cannulation practices in 171 dialysis units, a c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 9 شماره
صفحات -
تاریخ انتشار 2007