Comparison of use of the the Airtraq with direct laryngoscopy by paramedics in the simulated airway.

نویسندگان

  • Thomas A Nowicki
  • James C Suozzi
  • Mark Dziedzic
  • Richard Kamin
  • Stephen Donahue
  • Kenneth Robinson
چکیده

INTRODUCTION Paramedics often encounter patients with difficult airways requiring emergent airway management. OBJECTIVE The purpose of this study was to compare intubation utilizing the Airtraq with direct laryngoscopy (DL) in the manikin model. We evaluated the number of attempts, the time to successful intubation, and the Airtraq's learning curve. METHODS This was a randomized, crossover study involving paramedics. Each participant was given a standardized lecture and a demonstration of the Airtraq device. After a 5-minute practice session on a Laerdal Airway Management Trainer with the Airtraq and DL, participants managed the following four scenarios on a Laerdal SimMan manikin: 1) normal airway; 2) tongue edema; 3) cervical spine immobilization; and 4) repeated normal airway. Results were analyzed using the Wilcoxon signed rank test. RESULTS Thirty paramedics participated in this study. For scenario 1, there were no significant differences in either the number of attempts or the time to ventilation between the devices. For scenario 2, the mean time to ventilation was significantly faster, and fewer intubation attempts were observed with the Airtraq when compared with DL. For scenario 3, there were no significant differences in number of attempts and time to ventilation. Scenario 4 demonstrated significantly less time to ventilation and fewer intubation attempts with the Airtraq. A significant decrease in time to ventilation was observed with the Airtraq when comparing scenarios 1 and 4. CONCLUSIONS The Airtraq was shown to be equal to or faster than DL. The Airtraq has a rapid learning curve demonstrated by a significantly decreased time to ventilation between scenarios 1 and 4.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins

BACKGROUND Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq and Truview laryngoscopes may...

متن کامل

Subdural or subarachnoid catheter?

been two manikin studies that have described its performance. The device was evaluated in normal and simulated difficult airways. Until now, there have been no descriptions of its use in live subjects. We describe two patients in whom the Airtraq, compared with the Macintosh blade, provided superior views of the larynx facilitating endotracheal intubation. The first case was an anxious 59-yr-ol...

متن کامل

The Airtraq as a rescue airway device following failed direct laryngoscopy: a case series.

We report the successful use of the Airtraq as a rescue device following failed direct laryngoscopy, in patients deemed at increased risk for difficult tracheal intubation. In a series of seven patients, repeated attempts at direct laryngoscopy with the Macintosh blade, and the use of manoeuvres to aid intubation, such as the gum elastic bougie placement, were unsuccessful. In contrast, with th...

متن کامل

Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study.

The Airtraq Laryngoscope is a novel intubation device which allows visualisation of the vocal cords without alignment of the oral, pharyngeal and tracheal axes. We compared the Airtraq with the Macintosh laryngoscope in simulated easy and difficult laryngoscopy. Twenty-five anaesthetists were allowed up to three attempts to intubate the trachea in each of three laryngoscopy scenarios using a La...

متن کامل

Comparison of direct laryngoscopy to Pediatric King LT-D in simulated airways.

OBJECTIVES Previous reports have shown a high rate of ventilation failure via direct laryngoscopy as compared with the King LT-D airway. This difference is further divergent in the pediatric population. The goal of this study was to compare the difference in efficacy of ventilation by prehospital providers in a simulated environment between direct laryngoscopy and Pedi-King LT-D. METHODS In t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2009