Routine verification of RapidArc ® plans using Epiqa TM

نویسنده

  • Jan Hrbacek
چکیده

Epiqa TM is a program that allows to convert a dosimetric image acquired by an EPID into a dosemap and to compare the dosemap with a reference dose distribution. It is possible to utilize Epiqa for a verification of static as well as intensity modulated fields, including RapidArc ® fields. This text attempts to provide an overview of applied principles, describe the workflow, and discuss obtained results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient-specific quality assurance of RapidArc treatments: Portal prediction dosimetry compared with phantom studies

Purpose: To validate a locally fabricated phantom of Imatrixx-2D Array by comparing its results with ArcCheck phantom and comparing portal dosimetry measurements with the two phantom studies. Materials and Methods: Electronic Portal Imaging Devices and Epiqa software were used for portal dosimetry. An Imatrixx-2D array with a locally fabricated phantom and ArcCheck cylindrical phantom were used...

متن کامل

Monte Carlo simulation of RapidArc radiotherapy delivery.

RapidArc radiotherapy technology from Varian Medical Systems is one of the most complex delivery systems currently available, and achieves an entire intensity-modulated radiation therapy (IMRT) treatment in a single gantry rotation about the patient. Three dynamic parameters can be continuously varied to create IMRT dose distributions-the speed of rotation, beam shaping aperture and delivery do...

متن کامل

Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study

PURPOSE To verify the accuracy of volumetric arc therapy (VMAT) using the RapidArc™ device when switching patients from one single linear accelerator (linac) to a paired energy and mechanics "twin" linac without reoptimization of the original treatment plan. PATIENTS AND METHODS Four centers using 8 linacs were involved in this study. Seventy-four patients previously treated with the 6MV phot...

متن کامل

Prostate stereotactic body radiotherapy with simultaneous integrated boost: which is the best planning method?

BACKGROUND The delivery of a simultaneous integrated boost to the intra-prostatic tumour nodule may improve local control. The ability to deliver such treatments with hypofractionated SBRT was attempted using RapidArc (Varian Medical systems, Palo Alto, CA) and Multiplan (Accuray inc, Sunnyvale, CA). MATERIALS AND METHODS 15 patients with dominant prostate nodules had RapidArc and Multiplan p...

متن کامل

A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments.

The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010