Modified Lsm for Calibration of Measuring Apparatus
نویسندگان
چکیده
Modified least squares method (LSM) is developed that take into account errors in input standard signals for calibration of measuring devices. Calibration of the differential pressure gage by the standard control-point setting mechanisms is demonstrated in the paper as an example. The accuracy of the coefficient estimates changes when the errors of the control-point setting mechanisms are taken into account. Using the LSM in the classic form for the mentioned case gives wrong estimation errors in the final estimations of calibration curve coefficients. Therefore, for estimation of errors, characteristics of fractional errors are proposed use and as a variance of estimations errors guarantee the stability of the final estimation values.
منابع مشابه
Calibration of High Accuracy Class Standard Current Transformers
Main characteristic of high accuracy class current transformers is very small amplitude and phase errors (approximately 10 ppm). Such an error is a reason of complexity and sensitiveness of that metrological task. This paper presents a new method for high accuracy class current transformers calibration simultaneously with two different measuring apparatus. The method is presented as well as mea...
متن کاملCalibration of Neutron Measuring Devices in Differently Sized Rooms with Different-Structural Irradiation Apparatuses
The practical calibration rooms for neutron measuring devices are relatively small, where a large amount of room-reflected neutrons arise. Moreover the different structures of neutron irradiation apparatus influence the neutron spectrum and reference dose considerably. Therefore the influence of the neutron scattering was investigated in the three calibration rooms in different sizes and instal...
متن کاملDetermination of serum aspartate aminotransferase with pyridoxal 5'-phosphate in the Technicon SMAC and Du Pont aca compared and correlated with the IFCC recommended method.
Inexpensive improvements in continuous-flow analytical apparatus can eliminate some perplexing inconsistencies and limitations in the use of the Technicon SMAC instrument for measuring the activity in serum of aspartate aminotransferase (EC 2.6.1.1) in the presence of pyridoxal 5'-phosphate. In addition, a calibration procedure based on values for this enzyme obtained by a modified IFCC method ...
متن کاملA Least Squares Approach to Estimating the Average Reservoir Pressure
Least squares method (LSM) is an accurate and rapid method for solving some analytical and numerical problems. This method can be used to estimate the average reservoir pressure in well test analysis. In fact, it may be employed to estimate parameters such as permeability (k) and pore volume (Vp). Regarding this point, buildup, drawdown, late transient test data, modified Muskat method, interfe...
متن کاملQuantum calibration of measurement instrumentation.
By quantum calibration we name an experimental procedure apt to completely characterize an unknown measurement apparatus by comparing it with a few other calibrated apparatuses. Here we show how to achieve the calibration of an arbitrary measuring apparatus, by using it in combination with a tomographer in a correlation setup with an input bipartite system. The method is robust to imperfections...
متن کامل