Reactivity of potassium permanganate and tetraethylammonium chloride with mismatched bases and a simple mutation detection protocol.
نویسندگان
چکیده
Many mutation detection techniques rely upon recognition of mismatched base pairs in DNA hetero-duplexes. Potassium permanganate in combination with tetraethylammonium chloride (TEAC) is capable of chemically modifying mismatched thymidine residues. The DNA strand can then be cleaved at that point by treatment with piperidine. The reactivity of potassium permanganate (KMnO4) in TEAC toward mismatches was investigated in 29 different mutations, representing 58 mismatched base pairs and 116 mismatched bases. All mismatched thymidine residues were modified by KMnO4/TEAC with the majority of these showing strong reactivity. KMnO4/TEAC was also able to modify many mismatched guanosine and cytidine residues, as well as matched guanosine, cytidine and thymidine residues adjacent to, or nearby, mismatched base pairs. Previous techniques using osmium tetroxide (OsO4) to modify mismatched thymidine residues have been limited by the apparent lack of reactivity of a third of all T/G mismatches. KMnO4/TEAC showed no such phenomenon. In this series, all 29 mutations were detected by KMnO4/TEAC treatment. The latest development of the Single Tube Chemical Cleavage of Mismatch Method detects both thymidine and cytidine mismatches by KMnO4/TEAC and hydroxylamine (NH2OH) in a single tube without a clean-up step in between the two reactions. This technique saves time and material without disrupting the sensitivity and efficiency of either reaction.
منابع مشابه
Detection of single base mismatches of thymine and cytosine residues by potassium permanganate and hydroxylamine in the presence of tetralkylammonium salts.
In the presence of tetramethylammonium chloride, potassium permanganate specifically modifies mismatched thymines. Similarly, the modification of mismatched cytosines by hydroxylamine was enhanced by tetraethylammonium chloride. Modification followed by piperidine cleavage permits specific identification of the T and C mismatches and by extension, when the opposite DNA strand is analyzed, of A ...
متن کاملDetection of 100% of mutations in 124 individuals using a standard UV/Vis microplate reader: a novel concept for mutation scanning
We report the development of a simple and inexpensive assay for the detection of DNA polymorphisms and mutations that is based on the modification of mismatched bases by potassium permanganate. Unlike the chemical cleavage of mismatch assay, which also exploits the reactivity of potassium permanganate to detect genomic variants, the assay we describe here does not require a cleavage manipulatio...
متن کاملPotassium permanganate and tetraethylammonium chloride are a safe and effective substitute for osmium tetroxide in solid-phase fluorescent chemical cleavage of mismatch.
Whilst chemical cleavage of mismatch (CCM) detects all point mutations in DNA, its widespread use has been hampered by the complex multistage methodology and the need for toxic chemicals, in particular osmium tetroxide. Here we show that osmium tetroxide can be replaced by potassium permanganate, giving the same spectrum of mutation detection, but with greater sensitivity. The use of potassium ...
متن کاملChemical cleavage reactions of DNA on solid support: application in mutation detection
BACKGROUND: The conventional solution-phase Chemical Cleavage of Mismatch (CCM) method is time-consuming, as the protocol requires purification of DNA after each reaction step. This paper describes a new version of CCM to overcome this problem by immobilizing DNA on silica solid supports. RESULTS: DNA test samples were loaded on to silica beads and the DNA bound to the solid supports underwent ...
متن کاملDirect Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nucleic acids research
دوره 27 8 شماره
صفحات -
تاریخ انتشار 1999