Preliminary Result of Photon Counting Acquisition Scheme for Laser Pump/ X-ray Probe Experiments*

نویسندگان

  • J. He
  • Y. Zhang
  • Z. H. Gao
  • Y. F. Zhou
  • Y. F. Sui
  • H. Yue
  • J. S. Cao
  • Y. Tao
چکیده

R&D project has been initiated for a proposed ultralow emittance (~50pm.rad) synchrotron light source built in Beijing. The R&D includes the development of high repetition rate laser pump/X-ray probe for ultrafast dynamics detection in future source. In a typical laser pump/X-ray probe measurement, the X-ray pulse follows a laser pulse in adjustable delay. We are interested in the difference between laser on and laser off at different delay, which will snapshot dynamic process. To capture this trivial difference, it requires the acquisition system to single out the signal from this special X-ray pulse at adequate S/N ratio. For the R&D of high repetition rate pump-probe, we have set up a prototype counting acquisition system based on NIM modular electronics, which was tested in Beijing Synchrotron Radiation Facility (BSRF). The laser will be synchronized with a camshaft bunch at 124 kHz, a tenth of the revolution frequency. Avalanche Photo Diode (APD) was used to detect the X-ray pulse from this camshaft bunch due to its nanosecond response. Before the laser is delivered, we mimic the 124 kHz laseron signal. The signals from APD are separated by power dividers into two Constant Fraction Discriminator (CFD) input channels. The signal in laser-on/off channel is gated out using the 1.24MHz timing signal divided from 499.8 MHz RF signal, while the mimic laser-on signal gated out at 124 kHz. Multiplied by ten times, the mimic laser-on signal counts should be consistent with the laser-on+off counts, if our counting modular works well. We carried out this test at 1W1B wiggler beam line to measure the Fe fluorescence signal. The performance of our system is demonstrated in the good consistency between mimic laser on and laser on+off signals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector.

The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 ...

متن کامل

X-ray pump optical probe cross-correlation study of GaAs.

Ultrafast dynamics in atomic, molecular and condensed-matter systems are increasingly being studied using optical-pump, X-ray probe techniques where subpicosecond laser pulses excite the system and X-rays detect changes in absorption spectra and local atomic structure(1-3). New opportunities are appearing as a result of improved synchrotron capabilities and the advent of X-ray free-electron las...

متن کامل

Development of a hard X-ray delay line for X-ray photon correlation spectroscopy and jitter-free pump–probe experiments at X-ray free-electron laser sources

A hard X-ray delay line capable of splitting and delaying single X-ray pulses has been developed with the aim of performing X-ray photon correlation spectroscopy (XPCS) and X-ray pump-probe experiments at hard X-ray free-electron laser sources. The performance of the device was tested with 8.39 keV synchrotron radiation. Time delays up to 2.95 ns have been demonstrated. The feasibility of the d...

متن کامل

A Non-Demolition Photon Counting Method by Four-Level Inverted Y-Type Atom

The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015