NIST System for Measuring the Directivity Index of Hearing Aids under Simulated Real-Ear Conditions

نویسنده

  • Randall P Wagner
چکیده

The directivity index is a parameter that is commonly used to characterize the performance of directional hearing aids, and is determined from the measured directional response. Since this response is different for a hearing aid worn on a person as compared to when it is in a free field, directivity index measurements of hearing aids are usually done under simulated real-ear conditions. Details are provided regarding the NIST system for measuring the hearing aid directivity index under these conditions and how this system is used to implement a standardized procedure for performing such measurements. This procedure involves a sampling method that utilizes sound source locations distributed in a semi-aligned zone array on an imaginary spherical surface surrounding a standardized acoustical test manikin. The capabilities of the system were demonstrated over the frequency range of one-third-octave bands with center frequencies from 200 Hz to 8000 Hz through NIST participation in an interlaboratory comparison. This comparison was conducted between eight different laboratories of members of Working Group S3/WG48, Hearing Aids, established by Accredited Standards Committee S3, Bioacoustics, which is administered by the Acoustical Society of America and accredited by the American National Standards Institute. Directivity measurements were made for a total of six programmed memories in two different hearing aids and for the unaided manikin with the manikin right pinna accompanying the aids. Omnidirectional, cardioid, and bidirectional response patterns were measured. Results are presented comparing the NIST data with the reference values calculated from the data reported by all participating laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localization of virtual sound sources with bilateral hearing aids in realistic acoustical scenes.

Sound localization with hearing aids has traditionally been investigated in artificial laboratory settings. These settings are not representative of environments in which hearing aids are used. With individual Head-Related Transfer Functions (HRTFs) and room simulations, realistic environments can be reproduced and the performance of hearing aid algorithms can be evaluated. In this study, four ...

متن کامل

Predictability of speech-in-noise performance from real ear measures of directional hearing AIDS.

OBJECTIVE Inability to understand speech in noise has been cited repeatedly as the principal complaint of hearing aid users. While data exist documenting the benefit provided by hearing aids with directional microphones when listening to speech in noise, little work has been done to develop a standard clinical protocol for fitting these hearing aids. Our goal was to evaluate a clinical measure ...

متن کامل

The Prevalence of Ear Disease in Sensorineural Hearing Impaired Children Below 18 Years-Old in Deaf Welfare Clinic of Molavi Rehabilitation Center

Objectives: Hearing impairment in children is considered as an important public health problem. Auditory function in these children is poor and depends on their hearing aids efficacy and also their ears’ status. Hearing aids are very expensive and ear disease deteriorates its performance. Therefore detecting the ear disease and offering proper treatment is necessary. The aim of this study is to...

متن کامل

Conformity of the real-ear aided response with the target response from the DSL v5 formula

Objectives: Real ear measurement plays a critical role in children’s hearing aid fitting. This study aimed to evaluate the conformity of measured and predicted real-ear aided response (REAR) of prescribed formula desired sensation level (DSL) v5 Pediatric in children aged 4 to 7 years. Since there is limited information about the effect of the degree of hearing loss (DOHL), ethnicity, gender, a...

متن کامل

ارزیابی عملکرد آکوستیکی مانکن سر جهت استفاده در آزمون های تعیین قدرت کاهندگی صدای وسایل حفاظت شنوایی

Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate  tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 118  شماره 

صفحات  -

تاریخ انتشار 2013