Effect of sample instability on glycohemoglobin (HbA1) measured by cation-exchange chromatography.
نویسندگان
چکیده
We compared results for glycohemoglobin obtained from fresh whole blood or separated erythrocyte samples with results obtained after storage. We judged the storage condition to be acceptable ("stable") if the glycohemoglobin results after storage were within the 95 confidence interval (+/- SD) of the results obtained for the specimens on the day of venipuncture. Hemolysates can validly be stored for five months at -70 degrees C. Whole-blood samples stored at 4 degrees C remain stable for four days; whole blood treated with heparin or EDTA (but not oxalate) is stable for seven days. At 30 degrees C, whole blood or erythrocytes from some donors are stable for one day, but after two days and seven days, results are frequently higher. We confirmed previous findings that the separated erythrocytes can be stored at -20 degrees C for at least seven days. In addition, we compared the elution profiles for stored samples showing increased values.
منابع مشابه
Sources of variation in the column-chromatographic determination of glycohemoglobin (HbA1).
We studied the influence of many variables on the cation-exchange chromatographic determination of glycohemoglobin was minicolumns (HbA1) and with macrocolumns (HbA1a+b and HbA1c). Minicolumns are most sensitive to buffer composition. The best conditions are pH 6.78 and sodium, potassium, and phosphate concentrations of 54.8, and 36 mmol/L, respectively. In fact, there is no clear cut-off point...
متن کاملNon-separation assay for glycohemoglobin.
The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenc...
متن کاملGlycohemoglobin assays evaluated in a large-scale quality-control survey.
We report the results of a national quality-control survey on glycohemoglobin (GHb), monitored in France by the Société Française de Biologie Clinique on behalf of the authority of the "Agence du Médicament." A sample of lyophilized hemolysate was sent to 3109 laboratories. Results were obtained from 2770 laboratories. HbA1C, HbA1, and total GHb were measured by 50%, 24%, and 26% of the partici...
متن کاملSeparation of hemoglobin types by cation-exchange high-performance liquid chromatography.
The use of a recently developed cation-exchange HPLC packing material for the separation of hemoglobin types in human blood has been investigated. Adult and newborn hemolysates from normal individuals and from subjects with hemoglobin disorders were analyzed using a weak cation carboxymethyl-bonded phase on 5-micron-particle-size silica. Elution was accomplished using a Bistris (2-[bis(2-hydrox...
متن کاملImproved rapid procedure for simultaneous determinations of hemoglobins A1a, A1b, A1c, F, C, and S, with indication for acetylation or carbamylation by cation-exchange liquid chromatography.
Although the clinical utility of glycohemoglobin (HbA1c) as an indicator of blood glucose control is generally accepted, the use of cation-exchange liquid chromatography for its quantification is controversial, given numerous studies that show no correlation between HbA1c and other indicators of blood glucose control in uremic subjects. We report a specific cation-exchange liquid-chromatographi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 1 شماره
صفحات -
تاریخ انتشار 1982