Confocal microscopic examination of trabecular meshwork removed during ab externo trabeculectomy.
نویسندگان
چکیده
AIMS The aim of the ab externo trabeculectomy (AET) is to remove the external portion of the trabecular meshwork (ETM) responsible for the main aqueous outflow resistance in glaucoma patients, with no opening of the anterior chamber. ETM characteristics were evaluated with a confocal microscope. METHODS A prospective comparative observational case series was performed in 60 consecutive medically treated patients with primary open angle glaucoma and eight postmortem normal donors' eyes that underwent AET. Once deroofing the Schlemm' s canal (SC), a deeper dissection led to removal of a coherent membrane (ETM) which allowed satisfactory aqueous egress through the remaining intact internal trabecular meshwork (TM) layers. After fixation with acetone and immunostaining with anti-vimentin antibody, ETM were analysed with a confocal microscope. RESULTS Glaucomatous ETM (mean thickness: 29.5 (7.6) micro m) were characterised by a severe paucicellularity compared with the controls (respectively 37.3 (9.7) cells/area and 167.5 (24.9) cells/area, p<10(-4)). ETM analysis showed involvement of both cribriform and corneoscleral layers. ETM cell density was significantly decreased in case of preoperative fluorometholone instillation. CONCLUSION Paucicellularity of glaucomatous TM is confirmed by this original technique. Structural characteristics of the ETM, whose removal allows satisfactory aqueous egress, suggest that aqueous outflow resistance not only involves inner wall of SC and juxtacanalicular meshwork but also corneoscleral trabecular layers.
منابع مشابه
Trabeculectomy with fistula formation
Operations on the trabecular meshwork in order to reduce raised intraocular pressure are receiving increasing prominence. Redmond Smith (i960) opened the trabecular tissue by passing a nylon thread along the canal of Schlemm via an ab externo incision, and by a further incision and by picking up the distal end of the thread, he ruptured the trabecular meshwork by pulling on the thread like a bo...
متن کاملAb interno trabeculectomy: development of a novel device (Trabectome) and surgery for open-angle glaucoma.
PURPOSE To design an instrument to selectively remove trabecular meshwork and Schlemm's canal inner wall (SCIW), and demonstrate its effectiveness by histologic analysis of treated cadaveric human tissue. METHODS The design parameters of the instrument were the ability to permanently remove a segment of trabecular meshwork and Schlemm's canal inner wall without causing damage to surrounding t...
متن کاملDiathermo-trabeculotomy ab externo: indications and long-term results.
The authors present the results of 2 years' observation of 47 eyes operated with diathermo-trabeculotomy ab externo. This technique, based on a diathermic effect in association with trabeculotomy ab externo, allows an ample opening of Schlemm's canal and of the trabecular meshwork, with normalisation of intraocular pressure and outflow facility, for a period of up to 2 years, in open-angle and ...
متن کاملMicrohook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery
Trabeculotomy (LOT) is performed to reduce the intraocular pressure in patients with glaucoma, both in children and adults. It relieves the resistance to aqueous flow by cleaving the trabecular meshwork and the inner walls of Schlemm's canal. Microhook ab interno LOT (µLOT), a novel minimally invasive glaucoma surgery, incises trabecular meshwork using small hooks that are inserted through corn...
متن کاملAb interno trabeculectomy: patient selection and perspectives
Ab interno trabeculectomy is one among several recently introduced minimally invasive glaucoma surgeries that avoid a conjunctival incision and full-thickness sclerostomy involved in traditional glaucoma surgery. Ablation of the trabecular meshwork and inner wall of Schlemm's canal is performed in an arcuate fashion via a clear corneal incision, alone or in combination with phacoemulsification ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 86 9 شماره
صفحات -
تاریخ انتشار 2002