Approximations for Performance of Energy Detector and p-Norm Detector

نویسندگان

  • Vesh Raj S. Banjade
  • Chintha Tellambura
  • Hai Jiang
چکیده

Although the approximations based on the central limit theorem (CLT) for the detection probability (Pd) of the energy detector and of its more generalized cousin, the p-norm detector, are accurate for large sample sizes, their accuracy is poor otherwise. A recent work has addressed this problem by developing a cube-of-Gaussian approximation (CGA). However, CGA may not be the only option and thus this letter investigates five other classical approximations for deriving Pd . They tightly match the exact values even for few samples and thus are more accurate than CLT. These approximations have been unnoticed in the signal detection research community and this letter aims at making them known to a wider audience. Because the range of their potential applications could be diverse, to demonstrate their utility, we derive a novel expression for the area under the receiver operating characteristic curve of the p-norm detector.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comprehensive Performance Analysis of Direct Detection Receivers inWDMASystems

In this work the performance of a wavelength division multiple access (WDMA) system with direct detection receiver is investigated. For this purpose, the probability of error in a WDMA network with OOK modulation considering crosstalk, ISI, photo detector noise and thermal noise is calculated and the effect of each on system performance is investigated. The system performance in presence of PIN...

متن کامل

Performance of $p$-Norm Detector in AWGN, Fading, and Diversity Reception

Performance analysis of the p-norm detector to date has been limited to ad hoc approximations, non-fading channels and Rayleigh fading. To overcome these limitations, we develop several analytical/numerical solutions for the detection probability Pd and the false alarm probability Pf , which are necessary to specify the receiver operating characteristic curves of the p-norm detector. First, for...

متن کامل

Energy Detection of Unknown Signals over Composite multipath/shadowing Fading Channels

In this paper, the performance analysis of an energy detector is exploited over composite multipath/shadowing fading channels, which is modeled by Rayleigh-lognormal (RL) distribution. Based on an approximate channel model which was recently proposed by the author, the RL envelope probability density function (pdf) is approximated by a finite sum of weighted Rayleigh pdfs. Relying on this inter...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE Communications Letters

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015