Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial

نویسندگان

  • Joon Kyu Lee
  • Sahnghoon Lee
  • Sae Hyung Chun
  • Ki Tae Kim
  • Myung Chul Lee
چکیده

BACKGROUND Femoral component rotation (FCR) is one of the most important factors in total knee arthroplasty. In this prospective study, we used three different techniques for FCR and analyzed their accuracy with postoperative axial computed tomography (CT) images. We also evaluated effect of FCR to clinical outcome. METHODS One hundred sixty-five patients were randomly allocated into three groups. In the measured resection group, FCR was set by externally rotating the axis 3° off the posterior femoral condylar axis. In the tensor group, a gap-tensioning device set at 20 lbf was used. In the block group, spacer blocks of various thicknesses were used. The FCR angle (FCRa) was measured on postoperative axial CT as an angle between the clinical transepicondylar and posterior condylar axes of the femoral component. Outliers were defined as FCRas deviated more than 3° either internally or externally. Postoperative 2 year clinical scores and knee range of motion were checked. RESULTS The tensor group had significantly better positioning of the femoral component to the neutral position compared with the measured resection group and the block group (mean FCRa: internal rotation 1.79, 0.43 and 2.63°, respectively, p < 0.001). The outliers were also least frequent in the tensor group (35, 16 and 40%, respectively, p = 0.02). There were no significant differences in postoperative 2 year clinical results among groups. CONCLUSIONS Gap technique with a 20-lbf tensor device was the most accurate and precise method for obtaining adequate FCR. Measured resection with 3° external rotation and gap technique with blocks could lead to internal rotation of the femoral component. Postoperative 2 year clinical results were not significantly different among groups with different techniques for FCR. TRIAL REGISTRATION The study was registered in the Clinical Research information Service (trial number: KCT0000129 ) in Korea. Registration date is 23rd of June, 2011.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

A clinical study of the rotational alignment of the femoral component in total knee arthroplasty

We describe here various surgical options to obtain a correct rotational alignment of femoral component in total knee arthroplasty (TKA). The correct rotational alignment is the key point to obtain a rectangular balanced flexion gap as well to have a good patellar tracking. For that reason, rotation alignment largely affects postoperative kinematic results particularly during flexion.

متن کامل

Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty.

BACKGROUND Computer navigation systems generally establish the rotational alignment axis of the femoral component on the basis of user-defined anatomic landmarks. However, navigation systems can also record knee kinematics and average alignment axes established with multiple techniques. We hypothesized that establishing femoral rotational alignment with the use of kinematic techniques is more a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017