Cadaver study of oesophageal insufflation with supraglottic airway devices during positive pressure ventilation in an obstructed airway.

نویسندگان

  • W Schmidbauer
  • H Genzwürker
  • O Ahlers
  • H Proquitte
  • T Kerner
چکیده

BACKGROUND Supraglottic airway devices (SADs) play an increasing role in airway management in clinical anaesthesia and emergency medicine. Until now, no data exist concerning the extent of oesophageal insufflation when oropharyngeal leak pressures are exceeded. METHODS Laryngeal masks LMA-Supreme™ and LMA-ProSeal™, laryngeal tubes LTS-D and LTS II, Combitube™, and I-Gel were inserted into unfixed human cadavers. The oesophagus was connected to a volumeter, while the trachea was closed surgically to simulate complete airway obstruction. Volumes of oesophageal insufflation resulting from pressure-controlled ventilation at inspiratory pressures of 20, 40, and 60 mbar were measured. RESULTS No oesophageal insufflation could be detected at a ventilation pressure of 20 mbar in any device. Using inspiratory pressures of 40 and 60 mbar, oesophageal insufflation occurred in all devices, with significantly higher volumes of intraoesophageal air for both laryngeal tubes. CONCLUSIONS The use of SADs with inspiratory pressures of 20 mbar appears to be safe regarding the risk of intragastric insufflation. Higher inspiratory pressures should be strictly avoided.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy

BACKGROUND The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux ...

متن کامل

Reflux during positive pressure ventilation via the laryngeal mask airway?

Sir,—We read with interest the pilot study by Valentine, Stakes and Bellamy [1] comparing lower oesophageal pH changes in patients managed with either the laryngeal mask airway (LMA) or tracheal tube during intermittent positive pressure ventilation (IPPV). However, we suggest that the following factors in their study design may have had an influence on their results. (1) The authors probably u...

متن کامل

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

Combination of tracheal gas insufflation and airway pressure release ventilation.

STUDY OBJECTIVE We hypothesized that the continuous gas flow administration delivered through an insufflation catheter positioned above the carina during airway pressure release ventilation (APRV) would facilitate carbon dioxide (CO2) elimination, resulting in normocarbia with a substantially reduced peak airway pressure (Paw). To test this hypothesis, we compared intermittent positive pressure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 109 3  شماره 

صفحات  -

تاریخ انتشار 2012