Retaining well-fixed cementless stem in the treatment of infected hip arthroplasty
نویسندگان
چکیده
Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2013.814013 Sir—I have read the Acta article: Retaining well-fixed cementless stem in the treatment of infected hip arthroplasty” by Lee et al. (2013). The authors present outcome in 19 patients with infected hip arthroplasties and a well-fixed cementless stem intraoperatively tested by a stem retractor. Treatment consisted of removal of the acetabular cup, liner and head, and implantation of a cup of a cement spacer. At a mean follow-up of 4 years 15 of 17 patients had no recurrence of infection. The authors stated that there have been no results of stem-retaining 2-staged revision in the literature. However, we have published a similar study reporting on 13 patients with infected hip arthroplasties and well-fixed stems (Anagnostakos et al. 2010). In all cases a preoperative bone scintigraphy excluded involvement of the stem. Intraoperatively, the stem fixation was also tested by a stem retractor. Treatment consisted of removal of the acetabular cup, liner and head, and implantation of an antibiotic-loaded cement spacer head. At a mean follow-up of 5 years the infection was healed in 11 of 12 cases.
منابع مشابه
Retaining well-fixed cementless stem in the treatment of infected hip arthroplasty
BACKGROUND AND PURPOSE Two-stage reconstruction, reimplantation after removal of an infected prosthesis, has been considered to be the gold standard for treatment of infected hip arthroplasty. However, during the removal of a well-fixed femoral stem, the proximal femur can be damaged and a sequestrum can be formed, which might lead to chronic osteomyelitis and difficulty in reimplantation. We w...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملChallenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کامل