An evaluation of the IDEEA™ activity monitor for estimating energy expenditure.
نویسندگان
چکیده
Objective estimates of activity patterns and energy expenditure (EE) are important for the measurement of energy balance. The Intelligent Device for Energy Expenditure and Activity (IDEEA) can estimate EE from the thirty-five postures and activities it can identify and record. The present study evaluated the IDEEA system's estimation of EE using whole-body indirect calorimetry over 24 h, and in free-living subjects using doubly-labelled water (DLW) over 14 d. EE was calculated from the IDEEA data using calibration values for RMR and EE while sitting and standing, both as estimated by the IDEEA system (IDEEA(est)) and measured by indirect calorimetry (IDEEA(meas)). Subjects were seven females and seven males, mean age 38·1 and 39·7 years, mean BMI 25·2 and 26·2 kg/m2, respectively. The IDEEA(est) method produced a similar estimate of EE to the calorimeter (10·8 and 10·8 MJ, NS), while the IDEEA(meas) method underestimated EE (9·9 MJ, P < 0·001). After removing data from static cycling, which the IDEEA was unable to identify as an activity, both the IDEEA(est) and IDEEA(meas) methods overestimated EE compared to the calorimeter (9·9 MJ, P < 0·001; 9·1 MJ, P < 0·05 and 8·6 MJ, respectively). Similarly, the IDEEA system overestimated EE compared to DLW over 14 d; 12·7 MJ/d (P < 0·01), 11·5 MJ/d (P < 0·01) and 9·5 MJ/d for the IDEEA(est), IDEEA(meas) and DLW, respectively. The IDEEA system overestimated EE both in the controlled laboratory and free-living environments. Using measured EE values for RMR, sitting and standing reduced, but did not eliminate, the error in estimated EE.
منابع مشابه
Validation of a Novel Physical Activity Assessment Device in Morbidly Obese Females
Assessment of physical activity in morbidly obese subjects is important especially in bariatric surgery. We examined the validity of Intelligent Device for Energy Expenditure and Activity (IDEEA) for measuring physical activity and sedentary behavior in morbidly obese women. Activity types, gait counts, and speed detected by the IDEEA monitor were compared to those reported by an observer. The ...
متن کاملImproving energy expenditure estimation for physical activity.
PURPOSE The purpose of this study was to validate the Intelligent Device for Energy Expenditure and Activity (IDEEA) for estimation of energy expenditure during a variety of activities. An additional aim was to improve the accuracy of the estimation of energy expenditure of physical activity based on second-by-second information of type, onset, and duration of activity. METHODS This study inc...
متن کاملAn artificial neural network model of energy expenditure using nonintegrated acceleration signals.
Accelerometers are a promising tool for characterizing physical activity patterns in free living. The major limitation in their widespread use to date has been a lack of precision in estimating energy expenditure (EE), which may be attributed to the oversimplified time-integrated acceleration signals and subsequent use of linear regression models for EE estimation. In this study, we collected b...
متن کاملEvaluations of Actiheart, IDEEA® and RT3 monitors for estimating activity energy expenditure in free-living women
Activity energy expenditure (AEE) during free-living conditions can be assessed using devices based on different principles. To make proper comparisons of different devices' capacities to assess AEE, they should be evaluated in the same population. Thus, in the present study we evaluated, in the same group of subjects, the ability of three devices to assess AEE in groups and individuals during ...
متن کاملAccuracy of multisensor activity monitors in normal versus high BMI African American children.
BACKGROUND Overweight children show different movement patterns during walking than normal-weight children, suggesting the accuracy of multisensory activity monitors may differ in these groups. METHODS Eleven normal and 15 high BMI African American children walked at 2, 4, 5, and 6 km/h on a treadmill wearing the Intelligent Device for Energy Expenditure and Activity (IDEEA) and SenseWear (SW...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of nutrition
دوره 109 1 شماره
صفحات -
تاریخ انتشار 2013