Fluorescent light effects on FWT-60 radiochromic film.
نویسندگان
چکیده
FWT-60 radiochromic film has been tested for colouration effects from fluorescent light sources and shown to produce a marked colouration when exposed to office fluorescent light sources showing an approximate 1 OD unit per 0.5 J m(-2) exposure to a broad ultraviolet (UV) UVA + UVB spectrum at the peak absorption wavelength. This produces a measurable and quantifiable response to UV exposure. By choosing an appropriate wavelength of readout or band pass, the level of sensitivity can be changed to match the application or exposure level measurement required. These levels of UV response are significantly higher in sensitivity than other radiochromic films such as Gafchromic MD-55 by an order of magnitude. This feature may be of use for measurement of integrated UV exposure from fluorescent lights when required and produces a quantifiable history of total exposure.
منابع مشابه
Absorption spectra analysis of exposed FWT-60 radiochromic film.
The visible absorption spectra of Radiachromic FWT-60 radiochromic film have been investigated to analyse the dosimetry characteristics of the film. The film is radiation sensitive to high absorbed doses. The visible absorption spectra of this film when exposed to photon radiation show a peak at 605 nm which is stable over the dose range of 0 Gy to 20 kGy. The radiation sensitive absorption spe...
متن کاملEffects of read-out light sources and ambient light on radiochromic film.
Both read-out light sources and ambient light sources can produce a marked effect on coloration of radiochromic film. Fluorescent, helium neon laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose coloration of 660 cGy h(-1), 4.3 cGy h(-1), 1.7 cGy h(-1) and 2.6 cGy h(-1) respectively. Direct sunlight, fluorescent light and incandescent ambient lig...
متن کاملUltraviolet radiation dosimetry with radiochromic film.
Radiochromic film is tested for its broad-band response to ultraviolet (UV) B (290-320 nm) and A (320 nm400 nm), visible and infrared radiation produced by a solar simulator and examined for dosimetry in ultraviolet radiation. Results show that MD-55-2 radiochromic film in solar and fluorescent light sources responds almost exclusively to broad-band UVA radiation with negligible colouration fro...
متن کاملPolarization effects on a high-sensitivity radiochromic film.
A new high-sensitivity radiochromic film has been tested for its polarization properties. Gafchromic HS film has been shown to produce a relatively small (less than 3%) variation in the optical density measured at 660 nm wavelength when the light source is fully linear polarized and the film is rotated through a 360 angle. Similar variations are seen when the detector is linearly polarized. If ...
متن کاملInvestigation of the Effect of Temperature, Dose Rate and Short-term Post-irradiation Change on the Response of Various Types of Dosimeters to Cobalt-60 Gamma Radiation for Quality Assurance in Thailand
The influences of combined effect of irradiation temperature from -80°C to 60°C and dose rate between 0.2 and 4 Gy/s on the gamma ray response of several commercial routine dosimeters (Harwell Red 4034, Gammachrome YR, FWT-60-00 radiochromic films, FWT-70-40 optical waveguides, GafChromic films, and Fuji CTA-FTR-125 films) were investigated for quality assurance in radiation processes. Besides,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 50 16 شماره
صفحات -
تاریخ انتشار 2005