High-frequency positive-pressure ventilation in neonates.
نویسندگان
چکیده
Twenty-five newborn infants with severe respiratory failure responding poorly to conventional mechanical ventilation were switched to high-frequency positive-pressure ventilation (HFPPV) at 90 to 180 cycle/min (mean 158), an estimated tidal volume less than or equal to 3 ml/kg body weight, an inspiratory time of 0.1 sec, and a PEEP of 3 to 17 cm H2O. In all infants, HFPPV increased PaO2 (mean 66 torr) and decreased PaCO2 (mean 14 torr) within 1 h. Fourteen hours after onset of treatment, the FIO2 requirement had decreased from 1.0 to 0.6 in all infants. Mean airway pressure (Paw) with HFPPV was usually less than or equal to Paw during conventional ventilation. In spite of the often high level of PEEP used, pneumothorax occurred in only 2 infants and bronchopulmonary dysplasia in 1. Eighteen (72%) infants survived and none died of respiratory failure. The use of HFPPV might be beneficial in neonates with severe respiratory failure that responds poorly to conventional therapy.
منابع مشابه
Recognizing the Need for Mechanical Ventilatory
RECOGNIZING THE NEED FOR MECHANICAL VENTILATORY SUPPORT Clinical Indications for Respiratory Failure Determining Effective Oxygenation and Ventilation GOALS OF NEWBORN AND PEDIATRIC VENTILATORY SUPPORT NONINVASIVE RESPIRATORY SUPPORT Noninvasive Nasal Continuous Positive Airway Pressure in Neonates Noninvasive Positive-Pressure Ventilation in Neonates CPAP and BiPAP in Pediatric Patients CONVEN...
متن کاملComparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome
Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...
متن کاملVentilator-induced pulse pressure variation in neonates.
During positive pressure ventilation, arterial pressure variations, like the pulse pressure variation (PPV), are observed in neonates. However, the frequency of the PPV does not always correspond with the respiratory rate. It is hypothesized that PPV is caused by cardiopulmonary interaction, but that this mismatch is related to the low respiratory rate/heart rate ratio. Therefore, the goal of t...
متن کاملتاثیر تهویه مصنوعی نوسانی با فرکانس بالا در نارسایی شدید تنفسی نوزادان
Despite improvement of mechanical ventilation devices for infants, lung injury still causes morbidity and mortality in many cases. To determine the effect of high frequency oscillatory ventilation (HFOV) in infants with severe respiratory failure, 10 neonates were evaluated prospectively. Mean gestational age of these patients was 35 weeks and alveolar-arterial oxygen gradient (A-aDo2) and the ...
متن کاملComparison of the Heated Humidified High-flow Nasal Cannula with Nasal Continuous Positive Airway Pressure as Primary Respiratory Support for Preterm Neonates: A Prospective Observational Study
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity in the management of respiratory distress in preterm neonates. However, it is not known whether it takes precedence over the gold standard nasal continuous positive airway pressure (NCPAP) in this age group as a primary mode of non-invasive ventilation (NIV). There is limited evidence ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 12 9 شماره
صفحات -
تاریخ انتشار 1984