MR enhancement of brain lesions: increased contrast dose compared with magnetization transfer.

نویسندگان

  • M Knauth
  • M Forsting
  • M Hartmann
  • S Heiland
  • T Balzer
  • K Sartor
چکیده

PURPOSE To compare image contrast and lesion conspicuity of enhancing intracranial lesions obtained with T1-weighted and magnetization transfer T1-weighted spin-echo sequences after administration of standard (0.1 mmol/kg body weight) and triple doses of gadobutrol. METHODS Twenty-four patients with a total of 34 enhancing intracranial lesions were studied with T1-weighted and magnetization transfer T1-weighted spin-echo MR imaging. An incremental dose technique was used with intravenous injections of 0.1 and 0.2 mmol/kg body weight gadobutrol. Lesion-to-white matter contrast and white matter-to-edema contrast were calculated. RESULTS The lesion-to-white matter contrast of the magnetization transfer T1-weighted studies was significantly higher than that of the T1-weighted studies when identical doses of gadobutrol were compared. The lesion-to-white matter contrast was not significantly different on the triple-dose T1-weighted study and the standard-dose magnetization transfer T1-weighted study. Two lesions were visible only on the standard-dose magnetization transfer T1-weighted and the triple-dose studies. CONCLUSION Standard-dose magnetization transfer T1-weighted and triple-dose T1-weighted spin-echo MR studies are equally well suited to increase the lesion-to-white matter contrast in patients with enhancing intracranial lesions. Triple-dose magnetization transfer T1-weighted studies further increase lesion-to-white matter contrast but do not show additional lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR of intracranial tumors: combined use of gadolinium and magnetization transfer.

PURPOSE To study the potential combined application of gadolinium and magnetization transfer in the MR imaging of intracranial tumors. METHODS Twenty-two patients were imaged at low field strength (0.1 T). Corresponding gradient-echo partial saturation images without and with magnetization transfer pulse were produced. Images with intermediate repetition times were obtained in 18 cases; five ...

متن کامل

Multiple sclerosis lesions: relationship between MR enhancement pattern and magnetization transfer effect.

PURPOSE To investigate the relationship between the enhancement pattern of a multiple sclerosis lesion and its magnetization transfer effect. METHODS Fifty-four lesions were chosen from 29 patients with multiple sclerosis on the basis of enhancement pattern on contrast-enhanced T1-weighted MR images. They included 14 homogeneously enhancing lesions, 26 nonenhancing lesions, and 14 ring-enhanc...

متن کامل

Single-dose gadolinium with magnetization transfer versus triple-dose gadolinium in the MR detection of multiple sclerosis lesions.

PURPOSE To compare the efficacy of single-dose gadolinium with magnetization transfer contrast (MTC) with that of triple-dose gadolinium in detecting enhancing multiple sclerosis lesions. METHODS Twenty-one patients with multiple sclerosis were examined with MR imaging first with 0.1 mmol/kg gadolinium (single dose) and then, after 24 to 72 hours, with 0.3 mmol/kg gadolinium (triple dose). T2...

متن کامل

Enhanced and unenhanced MR with magnetization transfer in multiple sclerosis.

PURPOSE To evaluate the use of magnetization transfer and the apparent enhancement of lesions on contrast-enhanced MR images in patients with multiple sclerosis. METHODS Contrast-enhanced T1-weighted spin-echo MR images obtained in 20 patients with relapsing-remitting multiple sclerosis, with and without magnetization transfer, were evaluated to determine the number of enhancing plaques. Comp...

متن کامل

T1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.

PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 17 10  شماره 

صفحات  -

تاریخ انتشار 1996