Endoscopic ultrasound-guided biliary drainage with a novel fine-gauge balloon catheter: one-step placement technique.

نویسندگان

  • Takeshi Ogura
  • Tatsushi Sano
  • Saori Onda
  • Daisuke Masuda
  • Akira Imoto
  • Kazuh de Higuchi
چکیده

with a novel fine-gauge balloon catheter: one-step placement technique During endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), it is necessary to dilate the fistula [1]. Graded dilation with a 4-Fr cannula and 6and 7-Fr bougie dilators is relatively easily performed, and this stepwise procedure appears to be safe [2]. On the other hand, the use of a needle knife for fistula dilation in endoscopic ultrasound-guided biliary drainage (EUS-BD) may be associated with post-procedural adverse events [3]. These procedures have the potential to cause bile leakage because only the guidewire is placed between the bile duct and intestine across the abdominal cavity during the exchange of devices. There is a great need for a simplified technique to avoid such adverse events. A novel balloon catheter (ZARA; Century Medical, Tokyo, Japan) has two unique characteristics (●" Fig.1). First, the tip of the balloon catheter is only 3Fr in diameter and tapered. Second, the surface of the balloon catheter is rough. Therefore, the device is easily inserted following puncture with a 19-gauge needle, and during balloon dilation, the characteristics of the surface may be of clinical benefit in preventing malposition of the dilation site. An 80-year-old man was admitted because of vomiting and obstructive jaundice due to unresectable pancreatic cancer, which was obstructing the duodenum. First, we performed duodenal stenting. Next, we punctured the intrahepatic bile duct with a 19-gauge fine-needle aspiration needle and inserted a 0.025-inch stiff guidewire. The novel balloon catheter could then be smoothly inserted into the duodenum across the stricture site and duodenal stent. We dilated the stricture and duodenal stent to place the metallic stent, after which we used the novel balloon catheter to dilate the intrahepatic bile duct (●" Fig.2) and stomach wall (●" Fig.3). A metallic stent delivery system was then inserted in antegrade fashion and successfully placed at the lower bile duct. Finally, we performed the EUS-HGS (●" Fig.4). No adverse events occurred. Fig.2 Dilation of the intrahepatic bile duct wall. Fig.1 The tip of this balloon catheter is only 3Fr in diameter and tapered. The surface of the balloon catheter is rough.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EUS-guided pseudocyst drainage as a one-step procedure using a novel multiple wire insertion technique.

technique of endoscopic ultrasound (EUS)-guided pseudocyst drainage as a one-step procedure using a novel multiple wire insertion technique facilitated by the double-lumen biliary cytology brush catheter (Cook Medical, Winston-Salem, North Carolina, USA). Six symptomatic patients underwent EUS-guided pseudocyst drainage using the novel multiple wire insertion technique (●" Video 1). After ensur...

متن کامل

Novel wire-guided fine-gauge bougie dilator for transpapillary or endoscopic ultra- sonography-guided biliary drainage

Endoscopic management of biliary stricture generally requires dilation using devices such as an endoscopic retrograde cholangiopancreatography (ERCP) balloon dilation catheter before stenting [1]. Endoscopic ultrasonography (EUS)guided biliary drainage (EUS-BD) also requires fistula dilation before stenting. Recently, ultraslim balloon catheters [1] and diathermic dilators [2] have also been de...

متن کامل

Novel wire-guided fine-gauge bougie dilator for transpapillary or endoscopic ultrasonography-guided biliary drainage.

Endoscopic management of biliary stricture generally requires dilation using devices such as an endoscopic retrograde cholangiopancreatography (ERCP) balloon dilation catheter before stenting [1]. Endoscopic ultrasonography (EUS)guided biliary drainage (EUS-BD) also requires fistula dilation before stenting. Recently, ultraslim balloon catheters [1] and diathermic dilators [2] have also been de...

متن کامل

Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle

Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-...

متن کامل

Endoscopic ultrasound-guided gastroenterostomy: Are we ready for prime time?

Interventional endoscopic ultrasonography (EUS) is currently becoming the less invasive therapeutic approach for the drainage of pancreatic fluid collections, of acute cholecystitis in patients unfit for surgery and for biliary drainage after failed endoscopic retrograde cholangiopancreatography. In addition, EUS-guided gastroenterostomy (EUS-GE) has recently emerged as a feasible procedure to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 47 Suppl 1 UCTN  شماره 

صفحات  -

تاریخ انتشار 2015