Cross contamination of intramyocellular lipid signals through loss of bulk magnetic susceptibility effect differences in human muscle using (1)H-MRSI at 4 T.

نویسندگان

  • Min-Hui Cui
  • Jong-Hee Hwang
  • Vlad Tomuta
  • Zhengchao Dong
  • Daniel T Stein
چکیده

Cross contamination of intramyocellular lipid (IMCL) signals through loss of bulk magnetic susceptibility (BMS) differences was detected in human muscles using proton magnetic resonance spectroscopic imaging ((1)H-MRSI) at 4 T by varying nominal voxel sizes on healthy subjects. In soleus muscle the IMCL content estimated in 1.00-ml-sized voxels was 15% and 30% higher than that in 0.25-ml voxels for nonobese (P < 0.05) and obese (P < 0.01) subjects, respectively, whereas no effect was observed on IMCL estimation in tibialis posterior (TP) and tibialis anterior (TA) regions for different voxel sizes. The unbiased 0.25-ml voxel size (1)H-MRSI method was applied to measure IMCL content in nonobese sedentary (NOB-Sed), moderately trained (Ath), sedentary obese (OB), and Type 2 diabetic mellitus (DM) subjects. IMCL content in soleus was greatest in OB, with decreasing content in DM, Ath, and NOB-Sed, respectively (12.6 +/- 1.6, 9.7 +/- 1.8, 7.4 +/- 1.0, 4.9 +/- 0.5 mmol/kg wet wt; P < 0.05 by ANOVA; P < 0.05 OB vs. NOB-Sed or Ath). In TA, IMCL was equivalently elevated in DM and OB, which was higher than in Ath or NOB-Sed, respectively (4.2 +/- 0.4 and 4.2 +/- 0.7 vs. 2.7 +/- 0.5 and 1.5 +/- 0.3 mmol/kg wet wt; ANOVA, P < 0.05; P < 0.05 DM or OB vs. NOB-Sed). We conclude that IMCL content is overestimated when voxel size exceeds 0.25 ml despite measurement by optimized high-resolution (1)H-MRSI at high field. When IMCL is measured unbiased by concomitant obesity, we find that it is strongly influenced by muscle type, training status, and the presence of obesity and Type 2 diabetes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross contamination of intramyocellular lipid signals through loss of bulk magnetic susceptibility effect differences in human muscle using H-MRSI at 4 T

Cui M-H, Hwang J-H, Tomuta V, Dong Z, Stein DT. Cross contamination of intramyocellular lipid signals through loss of bulk magnetic susceptibility effect differences in human muscle using H-MRSI at 4 T. J Appl Physiol 103: 1290–1298, 2007. First published August 2, 2007; doi:10.1152/japplphysiol.01088.2006.—Cross contamination of intramyocellular lipid (IMCL) signals through loss of bulk magnet...

متن کامل

Reproducibility of single- and multi-voxel 1H MRS measurements of intramyocellular lipid in overweight and lean subjects under conditions of controlled dietary calorie and fat intake.

The reproducibility of repeated single-voxel 1H MRS (SV-MRS) and spectroscopic imaging (MRSI) measurements of intramyocellular lipid (IMCL) in the tibialis anterior muscle of five lean and five overweight female Caucasians, during 7 days of controlled dietary fat and calorie intake, was assessed at 1.5 T. Duplicate measures of IMCL relative to total muscle creatine (IMCL/tCr) obtained 3 days ap...

متن کامل

Quantification of lipids in human lower limbs using yellow bone marrow as the internal reference: gender-related effects.

The main purpose of this study was to determine and compare extra- and intramyocellular (IMCL) lipids content in the calf and thigh muscles of normal male and female volunteers using high-spatial-resolution magnetic resonance spectroscopic imaging (MRSI). The study groups consisted of 10 females and 10 males. The subjects were healthy and normal-weight. Fat (yellow bone marrow) was used as the ...

متن کامل

(1)H spectroscopic imaging of human brain at 3 Tesla: comparison of fast three-dimensional magnetic resonance spectroscopic imaging techniques.

PURPOSE To investigate the signal-to-noise-ratio (SNR) and data quality of time-reduced three-dimensional (3D) proton magnetic resonance spectroscopic imaging ((1)H MRSI) techniques in the human brain at 3 Tesla. MATERIALS AND METHODS Techniques that were investigated included ellipsoidal k-space sampling, parallel imaging, and echo-planar spectroscopic imaging (EPSI). The SNR values for N-ac...

متن کامل

Relationship between Insulin Sensitivity and Muscle Lipids may Differ with Muscle Group and Ethnicity.

Intramyocellular lipid (IMCL) has been inversely associated with insulin sensitivity in some, but not all, studies. This study utilized fast, high-resolution, magnetic resonance spectroscopic imaging (MRSI) to: investigate relationships between muscle lipids (IMCL and extramyocellular lipid (EMCL)) and insulin sensitivity in muscles of varying oxidative capacity, explore ethnic differences in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 103 4  شماره 

صفحات  -

تاریخ انتشار 2007