An Investigation on Cooling of CZT Co-Planar Grid Detectors

نویسندگان

  • J. V. Dawson
  • J. R. Wilson
  • K. Zuber
چکیده

The effect of moderate cooling on CdZnTe semiconductor detectors has been studied for the COBRA experiment. Improvements in energy resolution and low energy threshold were observed and quantified as a function of temperature. Leakage currents are found to contribute typically ∼5 keV to the widths of photopeaks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Results from Performance Studies of Frisch-Grid CdZnTe Detectors

New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...

متن کامل

Charge sharing in common-grid pixelated CdZnTe detectors

The charge sharing effect in pixelated CdZnTe (CZT) detectors with a common anode steering grid has been studied. The impact on energy resolution of weighting potential cross-talk and ballistic deficit due to cathode signal shaping has been investigated. A detailed system modeling package considering charge induction, electronic noise, pulse shaping, and ASIC triggering procedures has been deve...

متن کامل

Thick CZT Detectors for Space-Borne X-ray Astronomy

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to ∼600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors ...

متن کامل

Stability and Characteristics of Large CZT Coplanar Electrode Detectors

The single polarity charge sensing method based on coplanar grid electrodes has demonstrated promising results on CZT detectors having volumes of ~1 cm. This paper presents the performance of two coplanar grid CZT detectors having dimensions of 1.5 1 5 1.0 cm2, among the largest CZT spectrometers that have been reported. Energy resolutions of 2.3% and 2.0% full-width half-maximum were obtained ...

متن کامل

Simulation studies of CZT Detectors as Gamma-Ray Calorimeter

Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications Cadmium Zinc Telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and ∼1 MeV. They operate at room t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008