Universal sinus computed tomography protocol for diagnostic imaging and intraoperative navigation

نویسندگان

  • Joseph M. Hoxworth
  • Devyani Lal
چکیده

BACKGROUND Sinus computed tomography (CT) is performed for the diagnosis of paranasal sinus disease and to assess response to medical therapy. In addition, sinus CT is used for intraoperative imaging guidance. Multiple CTs increase cost and radiation exposure. OBJECTIVE To determine potential cost savings and radiation dose reduction that result from the use of a single universal sinus CT protocol for diagnostic imaging and intraoperative navigation. MATERIALS AND METHODS For sinus CT at the authors' institution, a single imaging protocol was begun and deemed acceptable by neuroradiologists and surgeons for diagnostic imaging and intraoperative guidance. The electronic medical record was queried over a 4-year period to determine the number of sinus CTs performed, dose-length products, referring providers' specialties, percentage of CTs used for intraoperative navigation, and the elapsed time between CT and surgery. RESULTS A total of 6187 sinus CTs were performed by using a 64-detector scanner during the study period (2759 women and 3428 men; 53.6 ± 16.7 years [mean ± SD]), and 596 endoscopic sinus surgery cases used imaging guidance, for which all the CTs were deemed technically adequate. The mean dose-length product for the CTs was 338.4 ± 31.9 mGy-cm (mean ± SD). Of the 3702 sinus CTs ordered by nonotolaryngology providers, 167 surgeries with intraoperative navigation (4.5%) were performed. A higher percentage of CT referrals from sinus surgeons (23.9%) and other otolaryngology providers (11.4%) was used for imaging guidance (p < 0.0001). The time interval between sinus CT and surgery was greatest for nonotolaryngology providers (63.1 days, p < 0.01). Based on Medicare reimbursement, the total estimated saving was $147,628. CONCLUSIONS Adopting a single universal sinus CT protocol for diagnostic imaging and intraoperative navigation can be an effective means of decreasing cost and radiation exposure. However, successful implementation must take into account multiple practice-based considerations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Intraoperative IGS/CT updates for complex endoscopic frontal sinus surgery.

INTRODUCTION Computer-aided surgery (CAS) systems integrate endoscopic visualization with real-time localization based on preoperative imaging. One short-coming of the current systems is the lack of real-time, radiographic assessment of surgical changes. We describe the potential applications of xCAT, a new intraoperative mobile volume CT scanner and its utility in providing surgical navigation...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015