PET physiological measurements using constant infusion.

نویسنده

  • R E Carson
چکیده

A wide range of study designs can be used with positron emission tomography methods to provide quantitative measurements of physiological parameters. While bolus injection of tracer is the conventional approach, use of combined bolus plus constant infusion provides a number of advantages for receptor-binding tracers. Of recent interest is the use of this approach to dynamically follow the displacement of tracer during in vivo changes in neurotransmitter concentrations. This paper provides an overview of the tradeoffs in using bolus/infusion methods versus conventional bolus injection for receptor binding studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deciphering PDT-induced inflammatory responses using real-time FDG-PET in a mouse tumour model.

Dynamic positron emission tomography (PET), combined with constant infusion of 2-deoxy-2-[(18)F]fluoro-d-glucose (FDG), enables real-time monitoring of transient metabolic changes in vivo, which can serve to understand the underlying physiology. Here we investigated characteristic changes in the tumour FDG-uptake profiles in relation to acute localized inflammatory responses induced by photodyn...

متن کامل

Quantifying Myocardial Glucose Use with PET

In this study, we compared the accuracy of the rate of myocardial glucose use (rMGU) measured using PET and 1-11C-glucose with the rate measured using PET and the more conventional tracer 18F-FDG. Methods: PET measurements of myocardial tracer uptake (K, in mL/g/min) and rMGU (in nmol/ g/min) were obtained with 1-11C-glucose and 18F-FDG in 21 dogs using kinetic modeling and the Patlak graphical...

متن کامل

Hepatic galactose metabolism quantified in humans using 2-18F-fluoro-2-deoxy-D-galactose PET/CT.

UNLABELLED Accurate quantification of regional liver function is needed, and PET of specific hepatic metabolic pathways offers a unique method for this purpose. Here, we quantify hepatic galactose elimination in humans using PET and the galactose analog 2-(18)F-fluoro-2-deoxy-d-galactose ((18)F-FDGal) as the PET tracer. METHODS Eight healthy human subjects underwent (18)F-FDGal PET/CT of the ...

متن کامل

A computerized Infusion Pump for control of tissue tracer concentration during Positron Emission Tomography in vivo Pharmacokinetic/Pharmacodynamic measurements

BACKGROUND A computer controlled infusion pump (UIPump) for regulation of target tissue concentration of radioactive compounds was developed for use in biological research and tracer development for PET. METHODS Based on observed tissue or plasma kinetics after a bolus injection of the tracer an algorithm calculates the infusion needed to obtain a specified target kinetic curve. A computer fe...

متن کامل

BRIEF REPORT Test–Retest Reproducibility of [C]-(+)-Propyl- Hexahydro-Naphtho-Oxazin Positron Emission Tomography Using the Bolus plus Constant Infusion Paradigm

We examined the reproducibility of using the constant infusion paradigm for equilibrium measurement of D2/3 receptors using [ C](+)-propyl-hexahydro-naphtho-oxazin (PHNO) positron emission tomography (PET). Six subjects were scanned with a bolus plus constant infusion (Kbol 5 80 minutes) of [ C]-(+)-PHNO. Binding potential (BPND) was computed using the equilibrium approach and compared to a sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine and biology

دوره 27 7  شماره 

صفحات  -

تاریخ انتشار 2000