Optimization of A Commercial PET Cyclotron For Increased 18F ̄ Production

نویسندگان

  • Jan Olof Bergstrom
  • Tomas Eriksson
چکیده

Commercial cyclotron systems used for 18F production through 18O (p, n) 18F reaction face several conflicting requirements that include: reliability/uptime, quantity of consumables, safety, cost and yield. With commercialization of PET tracer distribution, higher yield has become one of the most important requirements. Maximizing yield for commercial cyclotrons require engineering trade-off amongst several requirements, and often, to be conservative, significant design margin is kept while field feedback is collected. With maturing of technology, substantial experience has been obtained for a commercial cyclotron (PETtrace, GE Medical Systems), which is in use for several years. In this paper, we describe key elements of PETtrace commercial cyclotron technology undergoing enhancements, and share our works-in-progress experiments in performing critical engineering trade-offs to improve 18F yield. Three key parameters were tuned in this study within the design margin of the current equipment. First, we designed a second-generation target assembly with optimized 18O water volume for accepting increased beam currents while maintaining cooling performance. Second, we increased the beam current of the ion source. And finally, a new RF driver amplifier was designed to enhance the RF power ratings to enable higher beam currents. Initial tests performed in the factory indicate substantially higher yield performance (> 50%) reaching a peak yield of over 4 Ci per hour of bombardment in the new target. On dual targets, this extrapolates to 13.5 Ci/2hr of bombardment for a total target current of 120 μA. A target current of 100 μA is available in the existing design thus providing an 18F production capacity exceeding 11 Ci/2hr. The preliminary experimental results are promising and illustrate successful exploitation of design margin to achieve increased yield for a commercial cyclotron. Long-term studies to assess impact on life of ion source are underway along with a dedicated effort for achieving target currents in the excess of 120μA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental production and initial imaging of [18F]-14-Fluoro-6-thia-heptadecanoic acid ([18F]-FTHA) for myocardial performance [Persian]

Introduction: [18F]-6-thia-14-fluoro-heptadecanoic acid 3b, a free fatty acid, has been used in myocardial PET imaging. In order to establish an automated synthesis module for routine production in the country, a study performed for optimization of the production conditions as well as making modifications. Methods: [18F] Benzyl-14-Fluoro-6-thia-heptadecanoate 2b was prepared in no-carrier...

متن کامل

Production and quality control of [18F]-FDG in Iran [Persian]

The use of [18F]-2-FDG has been increasing in recent years. This agent was originally used for evaluation of CNS glucose uptake and pathologic conditions by positron emission tomography (PET). In view of increasing demand for this agent, its production has been started at cyclotron dept., Nuclear research center for agriculture & Medicine-Karaj Iran (NRCAM). In this paper, [18F]-FDG synth...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Production, formulation, quality control and primary biological studies of [18F]KF for skeletal PET scanning [Persian]

[18F]KF, considered as a reference standard for positron emission tomography of the skeletal system, was produced by the bombardment of enriched water ([18O]H2O>95%) with high energy protons in NRCAM cyclotron. After the extraction of fluoride from enriched water as KF, and passing it through microbial filter and fine adjustment of acidity and osmolality, it was converted into an injectab...

متن کامل

C-11 Choline and FDG PET/CT Imaging of Primary Cholangiocarcinoma – a Comparative Analysis

Objective(s): This study aimed to compare the diagnostic values of 11C-choline and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in patients with cholangiocarcinoma (CCA). Methods: This prospective study was conducted on 10 patients (6 males and 4 females), aged 42-69 years, suspected of having CCA based on CT or magnetic resonance imaging (MRI) resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002