Impact on rates and time to first central vascular-associated bloodstream infection when switching from open to closed intravenous infusion containers in a hospital setting.

نویسندگان

  • F Franzetti
  • B Borghi
  • F Raimondi
  • V D Rosenthal
چکیده

An open-label, prospective cohort, active healthcare-associated infection surveillance sequential study was conducted in four Italian intensive-care units. The aim was to determine the effect of switching from open (glass) to closed fully collapsible plastic intravenous (i.v.) infusion containers (Viaflo) on rate and time to onset of central venous catheter-associated bloodstream infections (CVC-BSI). A total of 1173 adult patients were enrolled. The CVC-BSI rate during the open container period was significantly higher than during the closed container period (8.2 vs. 3.5 BSI/1000 CVC days, relative risk 0.43, 95% confidence interval 0.22-0.84, P=0.01). The probability of developing a CVC-BSI was assessed over time comparing open and closed i.v. infusion containers. In the closed container period, it remained fairly constant (0.8% at days 1-3 to 1.4% at days 7-9) whereas during the open container period it increased (2% at days 1-3 to 5.8% at days 7-9). Overall, the chance of acquiring a CVC-BSI significantly decreased by 61% in the closed container period (Cox proportional hazard ratio 0.39, P=0.004).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of switching from an open to a closed infusion system on rates of central line-associated bloodstream infection: a meta-analysis of time-sequence cohort studies in 4 countries.

BACKGROUND We report a meta-analysis of 4 identical time-series cohort studies of the impact of switching from use of open infusion containers (glass bottle, burette, or semirigid plastic bottle) to closed infusion containers (fully collapsible plastic containers) on central line-associated bloodstream infection (CLABSI) rates and all-cause intensive care unit (ICU) mortality in 15 adult ICUs i...

متن کامل

Rate and time to develop first central line-associated bloodstream infections when comparing open and closed infusion containers in a Brazilian Hospital.

The objective of the study was to determine the effect of switching from an open (glass or semi-rigid plastic) infusion container to a closed, fully collapsible plastic infusion container (Viaflex) on rate and time to onset of central lineassociated bloodstream infections (CLABSI). An open-label, prospective cohort, active healthcare-associated infection surveillance, sequential study was condu...

متن کامل

Hospital costs of central line-associated bloodstream infections and cost-effectiveness of closed vs. open infusion containers. The case of Intensive Care Units in Italy

OBJECTIVES The aim was to evaluate direct health care costs of central line-associated bloodstream infections (CLABSI) and to calculate the cost-effectiveness ratio of closed fully collapsible plastic intravenous infusion containers vs. open (glass) infusion containers. METHODS A two-year, prospective case-control study was undertaken in four intensive care units in an Italian teaching hospit...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Epidemiology and infection

دوره 137 7  شماره 

صفحات  -

تاریخ انتشار 2009