Evaluation of five in-line hematocrit monitors.

نویسندگان

  • S Niles
  • R Cronbaugh
  • J Engle
  • J Ploessl
  • R Sutton
چکیده

Monitoring the hematocrit is essential during cardiopulmonary bypass for efficacious administration of blood products. The purpose of this study was to evaluate five cardiopulmonary bypass in-line monitors designed to display continuous hematocrit or hemoglobin values. The devices were evaluated for accuracy using an in vitro circuit primed with human blood while randomizing hematocrit, blood flow rate, and temperature. Hematocrits correlated significantly with the error in all the devices (p < 0.01). Over evaluation time, the error of the CDI, Gish, IBC, and MX2 increased significantly (p < 0.05). Temperature correlated significantly with the error of the Gish device (r = -0.49, p < 0.01). Blood flow correlated significantly with the Gish error (r = -0.24, p < 0.01). The Cobe device had a significantly smaller overall error than the other devices (p < 0.001). Device evaluation, based on a low mean error, a low percent error, a high correlation with the actual hematocrit, low correlations between mean error, blood flow, and temperature, and insignificant correlation between time and error, suggests that the Cobe device is more accurate for the continuous monitoring of hematocrit during cardiopulmonary bypass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of continuous mixed venous oxygen saturation and hematocrit monitors.

Four venous hemoglobin oxygen saturation monitors, two of which provide hemoglobin monitoring, were evaluated and compared to a performance standard (control) during cardiopulmonary bypass (CPB). The CDI 100 Hematocrit/Saturation Monitor, CDI 400, Cobe Hematocrit/Saturation Monitor, and the Baxter Bentley OxySat values were compared to the Radiometer Copenhagen OSM3 Hemoximeter and the Damon In...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Clinical comparisons of continuous venous oxygen saturation and hematocrit monitors in pediatric surgery.

Continuous venous oxygen saturation and hematocrit values are important parameters in assessing patient status while on cardiopulmonary bypass. Two devices used to measure continuous venous oxygen saturation while on cardiopulmonary bypass were compared to a control. The Bentley Oxysat meter and the Medtronic MX2 Oxygen Saturation and Hematocrit System were compared to the ABL500 blood gas mon...

متن کامل

Continuous venous oximetry: a comparative study between the CDI 100 and the Bentley OxySat II.

Two in-line oxygen saturation monitors, the CDI 100 and OxySat II, were evaluated in the clinical setting. Eighty-seven venous blood samples were drawn during 20 elective cardiopulmonary bypass procedures. Monitor readings were compared to OSM III co-oximeter values. The results revealed that saturation (%) determination was biased, -3.16 +/- 2.21 SD for the CDI 100 and -0.34 +/- 2.17 SD for th...

متن کامل

Expanding perfusion services through mobile point-of-care coagulation monitoring.

Current trends in cardiac surgery have challenged perfusionists to seek diversification of services. Point-of-care coagulation (POCC) monitoring represents a desirable area of perfusion service expansion. The purpose of the study was to create a series of hemostatic conditions to assess the functionality of POCC monitors to identify specific coagulopathies with identifiable profiles for algorit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1995