In vitro evaluation of pathogen-inactivated buffy coat-derived platelet concentrates during storage: psoralen-based photochemical treatment step-by-step.

نویسندگان

  • Mélanie Abonnenc
  • Giona Sonego
  • Julie Kaiser-Guignard
  • David Crettaz
  • Michel Prudent
  • Jean-Daniel Tissot
  • Niels Lion
چکیده

BACKGROUND The Intercept Blood SystemTM (Cerus) is used to inactivate pathogens in platelet concentrates (PC). The aim of this study was to elucidate the extent to which the Intercept treatment modifies the functional properties of platelets. MATERIAL AND METHODS A two-arm study was conducted initially to compare buffy coat-derived pathogen-inactivated PC to untreated PC (n=5) throughout storage. A four-arm study was then designed to evaluate the contribution of the compound adsorbing device (CAD) and ultraviolet (UV) illumination to the changes observed upon Intercept treatment. Intercept-treated PC, CAD-incubated PC, and UV-illuminated PC were compared to untreated PC (n=5). Functional characteristics were assessed using flow cytometry, hypotonic shock response (HSR), aggregation, adhesion assays and flow cytometry for the detection of CD62P, CD42b, GPIIb-IIIa, phosphatidylserine exposure and JC-1 aggregates. RESULTS Compared to fresh platelets, end-of-storage platelets exhibited greater passive activation, disruption of the mitochondrial transmembrane potential (Δψm), and phosphatidylserine exposure accompanied by a decreased capacity to respond to agonist-induced aggregation, lower HSR, and CD42b expression. The Intercept treatment resulted in significantly lower HSR and CD42b expression compared to controls on day 7, with no significant changes in CD62P, Δψm, or phosphatidylserine exposure. GPIIbIIIa expression was significantly increased in Intercept-treated platelets throughout the storage period. The agonist-induced aggregation response was highly dependent on the type and concentration of agonist used, indicating a minor effect of the Intercept treatment. The CAD and UV steps alone had a negligible effect on platelet aggregation. DISCUSSION The Intercept treatment moderately affects platelet function in vitro. CAD and UV illumination alone make negligible contributions to the changes in aggregation observed in Intercept-treated PC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Mirasol Pathogen Reduction Technology system and quality of platelets stored in platelet additive solution.

BACKGROUND The Mirasol Pathogen Reduction Technology system for platelets and plasma uses riboflavin and UV light to introduce irreparable lesions into nucleic acids thereby inhibiting pathogen and white blood cell replication and reducing the load of infectious pathogens. The aim of the present study was to evaluate low plasma buffy coat platelet concentrates obtained from the OrbiSac System a...

متن کامل

Conversion from Platelet-Rich Plasma Platelet Production to Buffy Coat Platelet Component Production: Benefits and Limitations

Blood transfusion centers are under considerable pressure to produce platelet concentrates with high quality and safety due to the short shelf life of 3-5 days as well as possible bacterial and viral contaminations. For a variety of reasons, many Europeans have changed their methods of component production from whole blood using the North American standard platelet-rich plasma method to the buf...

متن کامل

Comparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates

Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...

متن کامل

Evaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage

Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...

متن کامل

Use of 8-methoxypsoralen and long-wavelength ultraviolet radiation for decontamination of platelet concentrates.

Transmission of viral diseases through blood products remains an unsolved problem in transfusion medicine. We have developed a psoralen photochemical system for decontamination of platelet concentrates in which platelets are treated with long wavelength ultraviolet radiation (UVA, 320-400 nm) in the presence of 8-methoxypsoralen (8-MOP). Bacteria, RNA viruses, and DNA viruses ranging in genome ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood transfusion = Trasfusione del sangue

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2015