Investigation of soft-tissue stiffness alteration in denervated human tissue using an ultrasound indentation system.
نویسندگان
چکیده
BACKGROUND/OBJECTIVE Differences in soft-tissue stiffness may provide for a quantitative assessment and detection technique for pressure ulcers or deep-tissue injury. An ultrasound indentation system may provide a relatively convenient, simple, and noninvasive method for quantitative measurement of changes in soft-tissue stiffness in vivo. METHODS The Tissue Ultrasound Palpation System (TUPS) was used to quantitatively measure changes in soft-tissue stiffness at different anatomical locations within and between able-bodied persons and individuals with chronic spinal cord injury (SCI). The stiffness of soft tissue was measured at the ischial tuberosity, greater trochanter, posterior midthigh, and biceps brachii. Additionally, soft-tissue thickness and soft-tissue deformation were also measured. RESULTS Significant differences in soft-tissue stiffness were observed within the various anatomical locations tested, in both the able-bodied and SCI groups. Differences in soft-tissue stiffness were also observed between the 2 groups. Participants with SCI had significantly softer tissue in their buttock-thigh area. CONCLUSIONS TUPS is a clinically feasible technology that can reliably and effectively detect changes in soft-tissue stiffness. The study has provided a better understanding of the tissue mechanical response to external loading, specifically in the SCI population, suggesting the use of tissue stiffness as a parameter to detect and assess pressure-related soft-tissue injury.
منابع مشابه
A novel noncontact ultrasound indentation system for measurement of tissue material properties using water jet compression.
This study is aimed to develop a novel noncontact ultrasonic indentation system for measuring quantitative mechanical properties of soft tissues, which are increasingly important for tissue assessment and characterization. The key idea of this method is to use a water jet as an indenter to compress the soft tissue while at the same time as a medium for an ultrasound beam to propagate through. T...
متن کاملInvestigation of Shape Functions Role on the Mesh-free Method Application in Soft Tissue Elastography
In current study, The Mesh-free method based on weak-form formulation coupled with the ultrasound imaging technique is developed. This problem consists in computing the deformation of an elastic non-homogenous phantom by numerical methods (both Mesh-free and Finite Element) and converge their results to the measured deformation by the ultrasound. The shape functions of Mesh-free are approximate...
متن کاملQuasi-linear viscoelastic properties of fibrotic neck tissues obtained from ultrasound indentation tests in vivo.
BACKGROUND Hand palpation is a conventional way to assess and document soft tissue fibrosis. But it is semi-quantitative and subjective, so there is a need to develop quantitative and objective methods for this purpose. METHODS 105 patients with different degrees of radiation-induced fibrosis of soft tissue of the neck were assessed using an ultrasound indentation method. The force response w...
متن کاملAn optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues.
A novel noncontact indentation system with the combination of an air jet and optical coherence tomography (OCT) was presented in this paper for the quantitative measurement of the mechanical properties of soft tissues. The key idea of this method is to use a pressure-controlled air jet as an indenter to compress the soft tissue in a noncontact way and utilize the OCT signals to extract the defo...
متن کاملA new medical device to measure a stiffness of soft materials.
An objective in vivo measurement technique for assessing the material properties of soft tissue would be a valuabe tool in diagnosing dermatological pathologies. In order to make advancements in this field, a new hand-held device was designed to measure the stiffness of soft materials. The device measures the reaction forces experienced by the soft tissue under constant indentation deformations...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of spinal cord medicine
دوره 31 1 شماره
صفحات -
تاریخ انتشار 2008