Reduction of electron channeling in EDS using precession.
نویسندگان
چکیده
We demonstrated that EDS measurement can be significantly improved by precessing the electron beam, thereby reducing electron channeling effects. For a SrTiO3 specimen orientated along the [001] zone axis, the measured strontium to titanium atomic ratio was 0.74-0.80 using conventional EDS methods, and the ratio was improved to ~0.99 by precessing the electron beam for angles greater than 22.54 mRad. In ALCHEMI-like experiments in which the specimen was tilted to near two-beam condition, the strontium to titanium ratio was insensitive to the deviation from the Bragg condition using a precessed electron beam. Similar reduction of electron channeling effects was also observed in precession-assisted EDS measurements for an L21-ordered Fe2MnAl intermetallic alloy tilted to the [011] zone axis as well as near two-beam conditions.
منابع مشابه
بررسی تابش کانالی از بلورهای الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE
The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...
متن کاملSynthesis of Iron Oxide Nanoparticles using Borohydride Reduction
Iron oxide (Fe2O3) nanoparticles were synthesized by a simple approach using sodium borohydride (NaBH4) and Iron chloride hexahydrate (FeCl3.6H2O). Their physicochemical properties were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), X-ray diffraction (XRD) and electron dispersive spectroscopy (EDS). XRD pattern showed that the iron...
متن کاملSynthesis of Iron Oxide Nanoparticles using Borohydride Reduction
Iron oxide (Fe2O3) nanoparticles were synthesized by a simple approach using sodium borohydride (NaBH4) and Iron chloride hexahydrate (FeCl3.6H2O). Their physicochemical properties were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), X-ray diffraction (XRD) and electron dispersive spectroscopy (EDS). XRD pattern showed that the iron...
متن کاملCollection of Selected Area Electron Channeling Patterns (SACP) on an FEI Helios NanoLab Scanning Electron Microscope
Electron backscattered diffraction (EBSD) has replaced electron channeling and selected area electron channeling patterns (SACPs) for many scanning electron microscopy (SEM) based crystallographic studies, due to the rapid collection rates and high spatial resolution of EBSD. Nevertheless, a number of SEM techniques, for example electron channeling contrast imaging (ECCI), are better served usi...
متن کاملMeasurement Error in Atomic-Scale Scanning Transmission Electron Microscopy-Energy-Dispersive X-Ray Spectroscopy (STEM-EDS) Mapping of a Model Oxide Interface.
With the development of affordable aberration correctors, analytical scanning transmission electron microscopy (STEM) studies of complex interfaces can now be conducted at high spatial resolution at laboratories worldwide. Energy-dispersive X-ray spectroscopy (EDS) in particular has grown in popularity, as it enables elemental mapping over a wide range of ionization energies. However, the inter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultramicroscopy
دوره 126 شماره
صفحات -
تاریخ انتشار 2013