Widefield heterodyne interferometry using a custom CMOS modulated light camera.
نویسندگان
چکیده
In this paper a method of taking widefield heterodyne interferograms using a prototype modulated light camera is described. This custom CMOS modulated light camera (MLC) uses analogue quadrature demodulation at each pixel to output the phase and amplitude of the modulated light as DC voltages. The heterodyne interference fringe patterns are generated using an acousto-optical frequency shifter (AOFS) in an arm of a Mach-Zehnder interferometer. Widefield images of fringe patterns acquired using the prototype MLC are presented. The phase can be measured to an accuracy of ±6.6°. The added value of this method to acquire widefield images are discussed along with the advantages.
منابع مشابه
Patel, Rikesh and Achamfuo-Yeboah, Samuel and Light, Roger and Clark, Matt (2011) Widefield heterodyne interferometry using a custom CMOS modulated light
In this paper a method of taking widefield heterodyne interferograms using a prototype modulated light camera is described. This custom CMOS modulated light camera (MLC) uses analogue quadrature demodulation at each pixel to output the phase and amplitude of the modulated light as DC voltages. The heterodyne interference fringe patterns are generated using an acousto-optical frequency shifter (...
متن کاملPatel, Rikesh and Achamfuo-Yeboah, Samuel and Light, Roger and Clark, Matt (2012) Ultrastable heterodyne interferometer system using a CMOS modulated light
A novel ultrastable widefield interferometer is presented. This uses a modulated light camera (MLC) to capture and stabilise the interferogram in the widefield heterodyne interferometer. This system eliminates the contribution of piston phase to the interferogram without the need for common path optics and results in a highly stable widefield interferometer. The MLC uses quadrature demodulation...
متن کاملModulated CMOS camera for fluorescence lifetime microscopy.
Widefield frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) is a fast and accurate method to measure the fluorescence lifetime of entire images. However, the complexity and high costs involved in construction of such a system limit the extensive use of this technique. PCO AG recently released the first luminescence lifetime imaging camera based on a high frequency modulated CM...
متن کاملFrequency-modulated light scattering interferometry employed for optical properties and dynamics studies of turbid media
In the present work, fiber-based frequency-modulated light scattering interferometry (FMLSI) is developed and employed for studies of optical properties and dynamics in liquid phantoms made from Intralipid(®). The fiber-based FMLSI system retrieves the optical properties by examining the intensity fluctuations through the turbid medium in a heterodyne detection scheme using a continuous-wave fr...
متن کاملAlternative method for measuring the full-field refractive index of a gradient-index lens with normal incidence heterodyne interferometry.
A linearly/circularly polarized heterodyne light beam coming from a heterodyne light source with an electro-optic modulator in turn enters a modified Twyman-Green interferometer to measure the surface plane of a GRIN lens. Two groups of periodic sinusoidal segments recorded by a fast complementary metal-oxide semiconductor camera are modified, and their associated phases are derived with the un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 19 24 شماره
صفحات -
تاریخ انتشار 2011