Acute aortic dissection following non-structural failure of a prosthetic aortic valve.

نویسندگان

  • Andrew D Muir
  • Mark H D Danton
  • Gianfranco Campalani
چکیده

Malfunction of a prosthetic aortic valve is associated with a spectrum of potentially life threatening complications. In addition, the risk of aortic dissection increases following aortic valve replacement, which relates principally to aortic root pathology rather than prosthetic type or its functional status (Circulation 100 (1999) II-287). We report a case in which a high velocity turbulent jet in the proximal aorta, resulting from prosthetic leaflet entrapment caused intimal injury with subsequent type I dissection. This highlights the desirability for regular surveillance following aortic valve replacement, particularly in those patients with an 'at-risk' aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

Mid-term results of aortic root replacement using a self-assembled biological composite graft.

OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent...

متن کامل

Complications of aortic valve surgery: manifestations at CT and MR imaging.

Aortic valve replacement accounts for a significant portion of cardiac surgeries in the United States. Despite advances in prosthetic heart valve design, surgical technique, and postoperative care, complications after aortic valve replacement remain a leading cause of morbidity and mortality. Routine surveillance of prosthetic heart valves with transthoracic echocardiography (TTE), transesophag...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2003