Survey of dose area product received by patients undergoing common radiological examinations in four centers in Nigeria

نویسندگان

  • Bidemi I. Akinlade
  • Idowu P. Farai
  • Akintunde A. Okunade
چکیده

Patient dosimetry studies in diagnostic radiology in Nigeria have been on measurement of entrance skin dose and effective dose. Another important and easy to measure radiation dose descriptor that could be used to assess patient dose in radiological procedures is dose area product (DAP). Knowledge of DAP with location and projection of X-ray beam allows direct calculation of organ dose and effective dose. In this study, DAP for commonly performed radiological examinations (abdomen, chest, lumbo sacral joint, pelvis, paranasal sinus, and skull) in four diagnostic centers in Nigeria were determined. These centers comprise of three classes of health care center namely tertiary, private, and specialist hospitals. Mathematical method was used to determine DAP received by 336 patients undergoing radiological examinations at the selected diagnostic centers. The DAP received by patient from each radiological examination varies from center to center. The range factor (RF) of DAP for individual patients ranged from 1.55-4.56, while RF of DAP among the selected centers was 2.27-55.84. The highest RF of DAP (55.84) was obtained from X-ray examination of the chest. This variation was due to the application of anti-scatter grid, and high kVp and high mAs values for chest examination by only one of the centers. The very wide variation in DAP found among diagnostic centers in this survey showed that there is need to harmonize radiological techniques of common X-ray examination among different diagnostic centers. This would ensure optimal protection of patient against excessive radiation dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doses Received by Patients during Thorax X-Ray Examinations

Introduction Radiation exposures from diagnostic medical examinations are generally low and are almost always justified by the benefits of accurate diagnosis of possible disease conditions. Therefore, entrance skin dose (ESD), body organ dose (BOD), and effective dose (ED) from adult patients undergoing routine thorax posterior-anterior (PA) and thorax right lateral (RLAT) were estimated in Uni...

متن کامل

Film Reject Analysis and Radiation Doses Received by Patients in Selected Hospitals in Southwestern Nigeria

Introduction: A reject rate is the percentage of diagnostic images repeated due to errors during radiological examinations. The present study aimed to evaluate the patient radiation doses and analyze the film reject rate as part of quality assurance program in three diagnostic centers in Nigeria. Materials and Methods: This study was conducted in three hospitals, namely Federal Medical Center ...

متن کامل

Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...

متن کامل

Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

متن کامل

Assessment of Patient Absorbed Radiation Dose during Hysterosalpingography: A Pilot Study in Southwest Nigeria

Background: Hysterosalpingography (HSG) is an indispensable tool for diagnosing infertility in females. The procedure exposes female reproductive organs to ionizing radiation as the genitals are irradiated during the process. Investigating patient absorbed dose during the procedures is essential for effective radiological protection of the patient. Objective: This study aims to investigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012