Corrigendum to Performance of the BG1Luc ER TA method in a qHTS format.

نویسندگان

  • Patricia Ceger
  • David Allen
  • Ruili Huang
  • Menghang Xia
  • Warren Casey
چکیده

In 2012, the BG1Luc4E2 estrogen receptor (ER) transactivation (TA) method (BG1Luc ER TA) was accepted by U.S. regulatory agencies and the Organisation for Economic Co-operation and Development to detect substances with ER agonist activity. The method is now part of the Tier 1 testing battery in the Environmental Protection Agency's Endocrine Disruptor Screening Program. The BG1Luc ER TA method uses the BG1 ovarian cell line that endogenously expresses full-length ER (α and β) and is stably transfected with a plasmid containing four estrogen responsive elements upstream of a luciferase reporter gene. To allow increased throughput and testing efficiency, the BG1Luc ER TA ("BG1 manual") method was adapted for quantitative high-throughput screening (BG1 qHTS) in the U.S. Tox21 testing program. The BG1 qHTS test method was used to test approximately 10,000 chemicals three times each, and concentration-response data (n=15) were analyzed to evaluate test method performance. The balanced accuracy of the BG1 qHTS test method (97% [32/33]) was determined by comparing results to ER TA performance standards for the BG1 manual method. Concordance between the BG1 manual and qHTS methods was 92% (57/62) when calculated for a larger set of non-reference chemicals tested in both methods. These data demonstrate that the performance of the BG1 qHTS is similar to the currently accepted BG1 manual method, thereby establishing the utility of the BG1 qHTS method for identifying ER active environmental chemicals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Draft Performance Standards for the BG1Luc Estrogen Receptor (ER) Transactivation in Vitro Assay to Detect ER Antagonists for TG 457 INTRODUCTION

1. These Performance Standards (PS) accompany the BG1Luc Estrogen Receptor (ER) Transactivation (TA) Test Method for Identifying ER Agonists and Antagonists (TG 457) (1). Prior to the acceptance of a new test method for regulatory testing applications, validation studies are conducted to assess its reliability (i.e., the extent of intraand inter-laboratory reproducibility over time when perform...

متن کامل

Profiling of the Tox21 10K compound library for agonists and antagonists of the estrogen receptor alpha signaling pathway

The U.S. Tox21 program has screened a library of approximately 10,000 (10K) environmental chemicals and drugs in three independent runs for estrogen receptor alpha (ERα) agonist and antagonist activity using two types of ER reporter gene cell lines, one with an endogenous full length ERα (ER-luc; BG1 cell line) and the other with a transfected partial receptor consisting of the ligand binding d...

متن کامل

Investigating the Impact of Response Format on the Performance of Grammar Tests: Selected and Constructed

When constructing a test, an initial decision is choosing an appropriate item response format which can be classified as selected or constructed. In large-scale tests where time and finance are of concern, the use of response chosen known as multiple-choice items is quite widespread. This study aimed at investigating the impact of response format on the performance of structure tests. Concurren...

متن کامل

The Effect of Transitive Closure on the Calibration of Logistic Regression for Entity Resolution

This paper describes a series of experiments in using logistic regression machine learning as a method for entity resolution. From these experiments the authors concluded that when a supervised ML algorithm is trained to classify a pair of entity references as linked or not linked pair, the evaluation of the model’s performance should take into account the transitive closure of its pairwise lin...

متن کامل

Simulation and Analysis the Performance of 3970 Km DWDM Transmission Link Employing Optimized Semiconductor Optical Amplifiers

In this paper first we try to analysis the behavior ofthe SOAs in the optical networks and then have proposed anumerical simple model to simulate the behavior of thesemiconductor optical amplifiers. After that by employing thismodel as inline amplifier for a DWDM optical system, we havesimulated the transmission of 10 channels with bit rate 10 Gb/sup to distance 3970 km with RZ-DPSK modulation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ALTEX

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 2015